@@ -12,7 +12,7 @@
#define BME680_REG_TEMP_MSB 0x22
#define BME680_REG_PRESS_MSB 0x1F
-#define BM6880_REG_HUMIDITY_MSB 0x25
+#define BME680_REG_HUMIDITY_MSB 0x25
#define BME680_REG_GAS_MSB 0x2A
#define BME680_REG_GAS_R_LSB 0x2B
#define BME680_GAS_STAB_BIT BIT(4)
@@ -740,7 +740,7 @@ static int bme680_read_humid(struct bme680_data *data,
if (ret < 0)
return ret;
- ret = regmap_bulk_read(data->regmap, BM6880_REG_HUMIDITY_MSB,
+ ret = regmap_bulk_read(data->regmap, BME680_REG_HUMIDITY_MSB,
&tmp, sizeof(tmp));
if (ret < 0) {
dev_err(dev, "failed to read humidity\n");
Fix a define typo that instead of BME680_... it is saying BM6880_... Signed-off-by: Vasileios Amoiridis <vassilisamir@gmail.com> --- drivers/iio/chemical/bme680.h | 2 +- drivers/iio/chemical/bme680_core.c | 2 +- 2 files changed, 2 insertions(+), 2 deletions(-)