Message ID | 20240828205128.92145-3-vassilisamir@gmail.com (mailing list archive) |
---|---|
State | Changes Requested |
Headers | show |
Series | pressure: bmp280: Minor cleanup and interrupt support | expand |
On Wed, Aug 28, 2024 at 10:51:22PM +0200, Vasileios Amoiridis wrote: > The BM(P/E)28x devices have an option for soft reset which is also > recommended by the Bosch Sensortech BME2 Sensor API to be used before the > initial configuration of the device. ... > +static int bmp280_preinit(struct bmp280_data *data) > +{ With struct device *dev = data->dev; it will look better? > + unsigned int reg; > + int ret; > + ret = regmap_write(data->regmap, BMP280_REG_RESET, BMP280_RST_SOFT_CMD); > + if (ret) > + return dev_err_probe(data->dev, ret, > + "Failed to reset device.\n"); return dev_err_probe(dev, ret, "Failed to reset device.\n"); > + /* > + * According to the datasheet in Chapter 1: Specification, Table 2, > + * after resetting, the device uses the complete power-on sequence so > + * it needs to wait for the defined start-up time. > + */ > + fsleep(data->start_up_time); > + > + ret = regmap_read(data->regmap, BMP280_REG_STATUS, ®); > + if (ret) > + return dev_err_probe(data->dev, ret, > + "Failed to read status register.\n"); return dev_err_probe(dev, ret, "Failed to read status register.\n"); > + if (reg & BMP280_REG_STATUS_IM_UPDATE) > + return dev_err_probe(data->dev, -EIO, > + "Failed to copy NVM contents.\n"); return dev_err_probe(dev, -EIO, "Failed to copy NVM contents.\n"); > + return 0; > +} Yes, it's up to 84 characters long, but I think it improves readability.
On Thu, Aug 29, 2024 at 03:10:22PM +0300, Andy Shevchenko wrote: > On Wed, Aug 28, 2024 at 10:51:22PM +0200, Vasileios Amoiridis wrote: > > The BM(P/E)28x devices have an option for soft reset which is also > > recommended by the Bosch Sensortech BME2 Sensor API to be used before the > > initial configuration of the device. > > ... > > > +static int bmp280_preinit(struct bmp280_data *data) > > +{ > > With > > struct device *dev = data->dev; > > it will look better? > Yes, that could be used. > > + unsigned int reg; > > + int ret; > > > + ret = regmap_write(data->regmap, BMP280_REG_RESET, BMP280_RST_SOFT_CMD); > > + if (ret) > > > + return dev_err_probe(data->dev, ret, > > + "Failed to reset device.\n"); > > return dev_err_probe(dev, ret, "Failed to reset device.\n"); > ACK. > > + /* > > + * According to the datasheet in Chapter 1: Specification, Table 2, > > + * after resetting, the device uses the complete power-on sequence so > > + * it needs to wait for the defined start-up time. > > + */ > > + fsleep(data->start_up_time); > > + > > + ret = regmap_read(data->regmap, BMP280_REG_STATUS, ®); > > + if (ret) > > > + return dev_err_probe(data->dev, ret, > > + "Failed to read status register.\n"); > > return dev_err_probe(dev, ret, "Failed to read status register.\n"); > ACK. > > + if (reg & BMP280_REG_STATUS_IM_UPDATE) > > > + return dev_err_probe(data->dev, -EIO, > > + "Failed to copy NVM contents.\n"); > > return dev_err_probe(dev, -EIO, "Failed to copy NVM contents.\n"); > ACK. > > + return 0; > > +} > > Yes, it's up to 84 characters long, but I think it improves readability. > In all the previous cases though, shouldn't checkpatch.pl generate errors? I didn't notice that they were below 80 chars and I never checked more because checkpatch.pl didn't say anything... > -- > With Best Regards, > Andy Shevchenko > >
On Thu, Aug 29, 2024 at 09:00:04PM +0200, Vasileios Amoiridis wrote: > On Thu, Aug 29, 2024 at 03:10:22PM +0300, Andy Shevchenko wrote: > > On Wed, Aug 28, 2024 at 10:51:22PM +0200, Vasileios Amoiridis wrote: ... > > Yes, it's up to 84 characters long, but I think it improves readability. > > In all the previous cases though, shouldn't checkpatch.pl generate errors? No, much earlier than 100 characters relaxed limit was introduced, checkpatch stopped complaining on long string literals. > I didn't notice that they were below 80 chars and I never checked more > because checkpatch.pl didn't say anything... Exactly! This is old (6+ years?) feature.
diff --git a/drivers/iio/pressure/bmp280-core.c b/drivers/iio/pressure/bmp280-core.c index 9c705f2c4a7b..193a8fcbb5d8 100644 --- a/drivers/iio/pressure/bmp280-core.c +++ b/drivers/iio/pressure/bmp280-core.c @@ -965,6 +965,35 @@ static const unsigned long bme280_avail_scan_masks[] = { 0 }; +static int bmp280_preinit(struct bmp280_data *data) +{ + unsigned int reg; + int ret; + + ret = regmap_write(data->regmap, BMP280_REG_RESET, BMP280_RST_SOFT_CMD); + if (ret) + return dev_err_probe(data->dev, ret, + "Failed to reset device.\n"); + + /* + * According to the datasheet in Chapter 1: Specification, Table 2, + * after resetting, the device uses the complete power-on sequence so + * it needs to wait for the defined start-up time. + */ + fsleep(data->start_up_time); + + ret = regmap_read(data->regmap, BMP280_REG_STATUS, ®); + if (ret) + return dev_err_probe(data->dev, ret, + "Failed to read status register.\n"); + + if (reg & BMP280_REG_STATUS_IM_UPDATE) + return dev_err_probe(data->dev, -EIO, + "Failed to copy NVM contents.\n"); + + return 0; +} + static int bmp280_chip_config(struct bmp280_data *data) { u8 osrs = FIELD_PREP(BMP280_OSRS_TEMP_MASK, data->oversampling_temp + 1) | @@ -1082,6 +1111,7 @@ const struct bmp280_chip_info bmp280_chip_info = { .read_temp = bmp280_read_temp, .read_press = bmp280_read_press, .read_calib = bmp280_read_calib, + .preinit = bmp280_preinit, .trigger_handler = bmp280_trigger_handler, }; @@ -1202,6 +1232,7 @@ const struct bmp280_chip_info bme280_chip_info = { .read_press = bmp280_read_press, .read_humid = bme280_read_humid, .read_calib = bme280_read_calib, + .preinit = bmp280_preinit, .trigger_handler = bme280_trigger_handler, }; diff --git a/drivers/iio/pressure/bmp280.h b/drivers/iio/pressure/bmp280.h index 4e675401d61b..73516878d020 100644 --- a/drivers/iio/pressure/bmp280.h +++ b/drivers/iio/pressure/bmp280.h @@ -205,6 +205,9 @@ #define BMP280_REG_CONFIG 0xF5 #define BMP280_REG_CTRL_MEAS 0xF4 #define BMP280_REG_STATUS 0xF3 +#define BMP280_REG_STATUS_IM_UPDATE BIT(0) +#define BMP280_REG_RESET 0xE0 +#define BMP280_RST_SOFT_CMD 0xB6 #define BMP280_REG_COMP_TEMP_START 0x88 #define BMP280_COMP_TEMP_REG_COUNT 6
The BM(P/E)28x devices have an option for soft reset which is also recommended by the Bosch Sensortech BME2 Sensor API to be used before the initial configuration of the device. Link: https://github.com/boschsensortec/BME280_SensorAPI/blob/bme280_v3.5.1/bme280.c#L429 Signed-off-by: Vasileios Amoiridis <vassilisamir@gmail.com> --- drivers/iio/pressure/bmp280-core.c | 31 ++++++++++++++++++++++++++++++ drivers/iio/pressure/bmp280.h | 3 +++ 2 files changed, 34 insertions(+)