From patchwork Fri Aug 7 14:17:55 2020 Content-Type: text/plain; charset="utf-8" MIME-Version: 1.0 Content-Transfer-Encoding: 7bit X-Patchwork-Submitter: Eugene Zaikonnikov X-Patchwork-Id: 11705787 Return-Path: Received: from mail.kernel.org (pdx-korg-mail-1.web.codeaurora.org [172.30.200.123]) by pdx-korg-patchwork-2.web.codeaurora.org (Postfix) with ESMTP id 62A26722 for ; Fri, 7 Aug 2020 14:18:04 +0000 (UTC) Received: from vger.kernel.org (vger.kernel.org [23.128.96.18]) by mail.kernel.org (Postfix) with ESMTP id 35BBA22CF6 for ; Fri, 7 Aug 2020 14:18:04 +0000 (UTC) Authentication-Results: mail.kernel.org; dkim=pass (1024-bit key) header.d=trafsysas.onmicrosoft.com header.i=@trafsysas.onmicrosoft.com header.b="p068Tpno" Received: (majordomo@vger.kernel.org) by vger.kernel.org via listexpand id S1726388AbgHGOSD (ORCPT ); Fri, 7 Aug 2020 10:18:03 -0400 Received: from mail-eopbgr60107.outbound.protection.outlook.com ([40.107.6.107]:27790 "EHLO EUR04-DB3-obe.outbound.protection.outlook.com" rhost-flags-OK-OK-OK-FAIL) by vger.kernel.org with ESMTP id S1725815AbgHGOSD (ORCPT ); Fri, 7 Aug 2020 10:18:03 -0400 ARC-Seal: i=1; a=rsa-sha256; s=arcselector9901; d=microsoft.com; cv=none; b=k/S2V0/ZacFQlCPJ10p2KGVbmk2b/z5yOe22M7fq2kzEfNVfiHWnh7Ac+SsL9THA+e0oeXznfHt2uQt9gtWM7l7isgo16hKXlJONVq1tTnx5Rfo2TcYeXcbj4SsGTdpTTmr2+XGvoTc7calqgYSqkY88VMdDHeWH0nhsszOQklbY2BN5NqZ3PnbMfpegjZEoqfuo4E1iYntTmmCqgkhkshtzblSe4GAQPraj7u24BZiuVsVeroMC0Lp2WrHAzu0acXApQ2dUMqfFw2tgGgcN435F4o1TME0/ZeJJldmcV4h2oZ/quOr01h4OE8om3G7hW0TYwezl2gArteHQQ3XvEA== ARC-Message-Signature: i=1; a=rsa-sha256; c=relaxed/relaxed; d=microsoft.com; s=arcselector9901; h=From:Date:Subject:Message-ID:Content-Type:MIME-Version:X-MS-Exchange-SenderADCheck; bh=LfLjByAxJMQqHQzyeqkkJfNu8kyi+HgZtkalql5sXRQ=; b=J0lFUviWGYA7YWkJ1egF+uyMVHlmoVCJwxl6nw3BArBuG8H6weFQazhTAamgKJ7mz6HupNmevcmIJ9Zie8Qx/HbpWoWgFUHrRdbdFfS6NFDj9g/GPtI55B7TJBgPVmw18h7pXZ9SL+Kvj9P+SV/bZJIKbY8O82tXsk7Migh+CItGB2eSxJYGAX2xdvCAYjdsdMWTPbUqKlKM3w/zHlsgvxg1ISOyH5ZvFZdJ2S2I5sqbTxh/kMDyVak0btOZuTOGhUj/80c8eRZVLg+yrOfA2KfmEcAE/c3/2i2DXL1IE2yQx0m7+EpbPkSxOFje8Hz1cV826IfBoe+v1qMUKIdMUw== ARC-Authentication-Results: i=1; mx.microsoft.com 1; spf=pass smtp.mailfrom=norphonic.com; dmarc=pass action=none header.from=norphonic.com; dkim=pass header.d=norphonic.com; arc=none DKIM-Signature: v=1; a=rsa-sha256; c=relaxed/relaxed; d=trafsysas.onmicrosoft.com; s=selector2-trafsysas-onmicrosoft-com; h=From:Date:Subject:Message-ID:Content-Type:MIME-Version:X-MS-Exchange-SenderADCheck; bh=LfLjByAxJMQqHQzyeqkkJfNu8kyi+HgZtkalql5sXRQ=; b=p068Tpno8ZHLv6llyEcJKJglx9vCtLmgPOjwTyG6IQqKgAl8Ccm0G1BlbjdiX1tKyWmCx8XCd4booXo5I1bCNM7nFr2MwsE8rdaBHoYqzKn6yw48CrNaz4Xdd8DLNkYNIaP9+W3jkHbH8SitRvTyLra5c/eKAVvSzJsoXsu57CQ= Authentication-Results: vger.kernel.org; dkim=none (message not signed) header.d=none;vger.kernel.org; dmarc=none action=none header.from=norphonic.com; Received: from AM6PR06MB5430.eurprd06.prod.outlook.com (2603:10a6:20b:86::11) by AM6PR06MB5431.eurprd06.prod.outlook.com (2603:10a6:20b:87::17) with Microsoft SMTP Server (version=TLS1_2, cipher=TLS_ECDHE_RSA_WITH_AES_256_GCM_SHA384) id 15.20.3261.19; Fri, 7 Aug 2020 14:17:57 +0000 Received: from AM6PR06MB5430.eurprd06.prod.outlook.com ([fe80::3c50:d581:638e:fe8d]) by AM6PR06MB5430.eurprd06.prod.outlook.com ([fe80::3c50:d581:638e:fe8d%6]) with mapi id 15.20.3261.020; Fri, 7 Aug 2020 14:17:57 +0000 User-agent: mu4e 0.9.18; emacs 25.2.2 From: Eugene Zaikonnikov To: Jonathan Cameron Cc: development@norphonic.com, Hartmut Knaack , Lars-Peter Clausen , linux-iio Subject: [PATCH v10 1/2] iio: humidity: Add TI HDC20x0 support Date: Fri, 07 Aug 2020 16:17:55 +0200 Message-ID: <86imdu35gs.fsf@norphonic.com> X-ClientProxiedBy: SV0P279CA0030.NORP279.PROD.OUTLOOK.COM (2603:10a6:f10:12::17) To AM6PR06MB5430.eurprd06.prod.outlook.com (2603:10a6:20b:86::11) MIME-Version: 1.0 X-MS-Exchange-MessageSentRepresentingType: 1 Received: from sta-eugenez.norphonic.com (62.97.226.122) by SV0P279CA0030.NORP279.PROD.OUTLOOK.COM (2603:10a6:f10:12::17) with Microsoft SMTP Server (version=TLS1_2, cipher=TLS_ECDHE_RSA_WITH_AES_256_GCM_SHA384) id 15.20.3261.18 via Frontend Transport; Fri, 7 Aug 2020 14:17:56 +0000 X-Originating-IP: [62.97.226.122] X-MS-PublicTrafficType: Email X-MS-Office365-Filtering-Correlation-Id: 1b3a1498-18fa-4106-cb4d-08d83adcaeaa X-MS-TrafficTypeDiagnostic: AM6PR06MB5431: X-MS-Exchange-Transport-Forked: True X-Microsoft-Antispam-PRVS: X-MS-Oob-TLC-OOBClassifiers: OLM:9508; X-MS-Exchange-SenderADCheck: 1 X-Microsoft-Antispam: BCL:0; X-Microsoft-Antispam-Message-Info: 11PaNZm1rd/ywBOk8tZjAbJwgCbi02HjNW8M7ClXjfQRDCYYfJl9IdZ8SUh+Owo9wPF23C5wNaF/N9RFAWzqp9O7kPY4pgYjJfIC+Yv1XildzLwveqUKYAscScnnHnZwPM/VBGx4nL0wzTuKcBtfGj7DztHBzvFT3es59lsDG2Zv1Y4vYQxqDwuBHjJm5YCTuSrtmuiqihRdCBygs89vDgOC0i6YIztIvbRqs/FHiA/Gy2QIlkQahJ8HhFCZ41ERSvLH8TVq3icc0TfAcAlwuE+MzH8z0Nb2SINAgcx1/yLilm/z8oT96Qp3pRfUZ/LXRmZCHJex8G6gtvTpG87bq4ay9l5N5C1OWvKR+xBzXWmrHlSenBZITwbm1UnAku+eUfpxrgsnkNtNHlYtSuYgVw== X-Forefront-Antispam-Report: CIP:255.255.255.255;CTRY:;LANG:en;SCL:1;SRV:;IPV:NLI;SFV:NSPM;H:AM6PR06MB5430.eurprd06.prod.outlook.com;PTR:;CAT:NONE;SFTY:;SFS:(136003)(346002)(376002)(39830400003)(366004)(396003)(6486002)(2906002)(66946007)(8936002)(7696005)(2616005)(4001150100001)(956004)(66556008)(66476007)(52116002)(30864003)(54906003)(83380400001)(8676002)(6916009)(508600001)(36756003)(316002)(4326008)(26005)(86362001)(186003)(16526019)(5660300002)(966005);DIR:OUT;SFP:1102; X-MS-Exchange-AntiSpam-MessageData: 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 X-OriginatorOrg: norphonic.com X-MS-Exchange-CrossTenant-Network-Message-Id: 1b3a1498-18fa-4106-cb4d-08d83adcaeaa X-MS-Exchange-CrossTenant-AuthSource: AM6PR06MB5430.eurprd06.prod.outlook.com X-MS-Exchange-CrossTenant-AuthAs: Internal X-MS-Exchange-CrossTenant-OriginalArrivalTime: 07 Aug 2020 14:17:57.2249 (UTC) X-MS-Exchange-CrossTenant-FromEntityHeader: Hosted X-MS-Exchange-CrossTenant-Id: cbf3f496-45ad-415e-97cb-4e62d6cd974f X-MS-Exchange-CrossTenant-MailboxType: HOSTED X-MS-Exchange-CrossTenant-UserPrincipalName: CVu7ZGYa7mHohGO2sDmjCxEl6mZ76qsfdIGn38oQ2CpWKp/IHrtLZetnZbvDcijYAEO1al9/UI7t2gHVuC7oNg== X-MS-Exchange-Transport-CrossTenantHeadersStamped: AM6PR06MB5431 Sender: linux-iio-owner@vger.kernel.org Precedence: bulk List-ID: X-Mailing-List: linux-iio@vger.kernel.org Add driver support for HDC2010/2080 series devices and sysfs documentation for their heater element. HDC2010 is an integrated high-accuracy humidity and temperature sensor with very low power consumption. The device includes a resistive heating element. The temperature range is -40C to 125C with 0.2C accuracy. Humidity measurement is 0 to 100% with 2% RH accuracy. Signed-off-by: Eugene Zaikonnikov --- Heater capabilities are kept as IIO_CONST_ATTR for backwards compatibility (subject to further change). Changes since v9: - style and formatting changes after the feedback diff -uprN -X linux-5.3.8/Documentation/dontdiff linux-5.3.8/Documentation/ABI/testing/sysfs-bus-iio-humidity-hdc2010 linux-5.3.8_hdc2010/Documentation/ABI/testing/sysfs-bus-iio-humidity-hdc2010 --- linux-5.3.8/Documentation/ABI/testing/sysfs-bus-iio-humidity-hdc2010 1970-01-01 01:00:00.000000000 +0100 +++ linux-5.3.8_hdc2010/Documentation/ABI/testing/sysfs-bus-iio-humidity-hdc2010 2019-12-02 11:09:25.803326999 +0100 @@ -0,0 +1,9 @@ +What: /sys/bus/iio/devices/iio:deviceX/out_current_heater_raw +What: /sys/bus/iio/devices/iio:deviceX/out_current_heater_raw_available +KernelVersion: 5.3.8 +Contact: linux-iio@vger.kernel.org +Description: + Controls the heater device within the humidity sensor to get + rid of excess condensation. + + Valid control values are 0 = OFF, and 1 = ON. diff -uprN -X linux-5.3.8/Documentation/dontdiff linux-5.3.8/drivers/iio/humidity/hdc2010.c linux-5.3.8_hdc2010/drivers/iio/humidity/hdc2010.c --- linux-5.3.8/drivers/iio/humidity/hdc2010.c 1970-01-01 01:00:00.000000000 +0100 +++ linux-5.3.8_hdc2010/drivers/iio/humidity/hdc2010.c 2020-08-07 14:59:31.930027709 +0200 @@ -0,0 +1,353 @@ +// SPDX-License-Identifier: GPL-2.0+ +/* + * hdc2010.c - Support for the TI HDC2010 and HDC2080 + * temperature + relative humidity sensors + * + * Copyright (C) 2020 Norphonic AS + * Author: Eugene Zaikonnikov + * + * Datasheet: https://www.ti.com/product/HDC2010/datasheet + * Datasheet: https://www.ti.com/product/HDC2080/datasheet + */ + +#include +#include +#include +#include + +#include +#include + +#define HDC2010_REG_TEMP_LOW 0x00 +#define HDC2010_REG_TEMP_HIGH 0x01 +#define HDC2010_REG_HUMIDITY_LOW 0x02 +#define HDC2010_REG_HUMIDITY_HIGH 0x03 +#define HDC2010_REG_INTERRUPT_DRDY 0x04 +#define HDC2010_REG_TEMP_MAX 0x05 +#define HDC2010_REG_HUMIDITY_MAX 0x06 +#define HDC2010_REG_INTERRUPT_EN 0x07 +#define HDC2010_REG_TEMP_OFFSET_ADJ 0x08 +#define HDC2010_REG_HUMIDITY_OFFSET_ADJ 0x09 +#define HDC2010_REG_TEMP_THR_L 0x0a +#define HDC2010_REG_TEMP_THR_H 0x0b +#define HDC2010_REG_RH_THR_L 0x0c +#define HDC2010_REG_RH_THR_H 0x0d +#define HDC2010_REG_RESET_DRDY_INT_CONF 0x0e +#define HDC2010_REG_MEASUREMENT_CONF 0x0f + +#define HDC2010_MEAS_CONF GENMASK(2, 1) +#define HDC2010_MEAS_TRIG BIT(0) +#define HDC2010_HEATER_EN BIT(3) +#define HDC2010_AMM GENMASK(6, 4) + +struct hdc2010_data { + struct i2c_client *client; + struct mutex lock; + u8 measurement_config; + u8 interrupt_config; + u8 drdy_config; +}; + +enum hdc2010_addr_groups { + HDC2010_GROUP_TEMP = 0, + HDC2010_GROUP_HUMIDITY, +}; + +struct hdc2010_reg_record { + unsigned long primary; + unsigned long peak; +}; + +static const struct hdc2010_reg_record hdc2010_reg_translation[] = { + [HDC2010_GROUP_TEMP] = { + .primary = HDC2010_REG_TEMP_LOW, + .peak = HDC2010_REG_TEMP_MAX, + }, + [HDC2010_GROUP_HUMIDITY] = { + .primary = HDC2010_REG_HUMIDITY_LOW, + .peak = HDC2010_REG_HUMIDITY_MAX, + }, +}; + +static IIO_CONST_ATTR(out_current_heater_raw_available, "0 1"); + +static struct attribute *hdc2010_attributes[] = { + &iio_const_attr_out_current_heater_raw_available.dev_attr.attr, + NULL +}; + +static const struct attribute_group hdc2010_attribute_group = { + .attrs = hdc2010_attributes, +}; + +static const struct iio_chan_spec hdc2010_channels[] = { + { + .type = IIO_TEMP, + .address = HDC2010_GROUP_TEMP, + .info_mask_separate = BIT(IIO_CHAN_INFO_RAW) | + BIT(IIO_CHAN_INFO_PEAK) | + BIT(IIO_CHAN_INFO_OFFSET) | + BIT(IIO_CHAN_INFO_SCALE), + }, + { + .type = IIO_HUMIDITYRELATIVE, + .address = HDC2010_GROUP_HUMIDITY, + .info_mask_separate = BIT(IIO_CHAN_INFO_RAW) | + BIT(IIO_CHAN_INFO_PEAK) | + BIT(IIO_CHAN_INFO_SCALE), + }, + { + .type = IIO_CURRENT, + .info_mask_separate = BIT(IIO_CHAN_INFO_RAW), + .extend_name = "heater", + .output = 1, + }, +}; + +static int hdc2010_update_drdy_config(struct hdc2010_data *data, + char mask, char val) +{ + u8 tmp = (~mask & data->drdy_config) | val; + int ret; + + ret = i2c_smbus_write_byte_data(data->client, + HDC2010_REG_RESET_DRDY_INT_CONF, tmp); + if (ret) + return ret; + + data->drdy_config = tmp; + + return 0; +} + +static int hdc2010_get_prim_measurement_word(struct hdc2010_data *data, + struct iio_chan_spec const *chan) +{ + struct i2c_client *client = data->client; + s32 ret; + + ret = i2c_smbus_read_word_data(client, + hdc2010_reg_translation[chan->address].primary); + + if (ret < 0) + dev_err(&client->dev, "Could not read sensor measurement word\n"); + + return ret; +} + +static int hdc2010_get_peak_measurement_byte(struct hdc2010_data *data, + struct iio_chan_spec const *chan) +{ + struct i2c_client *client = data->client; + s32 ret; + + ret = i2c_smbus_read_byte_data(client, + hdc2010_reg_translation[chan->address].peak); + + if (ret < 0) + dev_err(&client->dev, "Could not read sensor measurement byte\n"); + + return ret; +} + +static int hdc2010_get_heater_status(struct hdc2010_data *data) +{ + return !!(data->drdy_config & HDC2010_HEATER_EN); +} + +static int hdc2010_read_raw(struct iio_dev *indio_dev, + struct iio_chan_spec const *chan, int *val, + int *val2, long mask) +{ + struct hdc2010_data *data = iio_priv(indio_dev); + + switch (mask) { + case IIO_CHAN_INFO_RAW: { + int ret; + + if (chan->type == IIO_CURRENT) { + *val = hdc2010_get_heater_status(data); + return IIO_VAL_INT; + } + ret = iio_device_claim_direct_mode(indio_dev); + if (ret) + return ret; + mutex_lock(&data->lock); + ret = hdc2010_get_prim_measurement_word(data, chan); + mutex_unlock(&data->lock); + iio_device_release_direct_mode(indio_dev); + if (ret < 0) + return ret; + *val = ret; + return IIO_VAL_INT; + } + case IIO_CHAN_INFO_PEAK: { + int ret; + + ret = iio_device_claim_direct_mode(indio_dev); + if (ret) + return ret; + mutex_lock(&data->lock); + ret = hdc2010_get_peak_measurement_byte(data, chan); + mutex_unlock(&data->lock); + iio_device_release_direct_mode(indio_dev); + if (ret < 0) + return ret; + /* Scaling up the value so we can use same offset as RAW */ + *val = ret * 256; + return IIO_VAL_INT; + } + case IIO_CHAN_INFO_SCALE: + *val2 = 65536; + if (chan->type == IIO_TEMP) + *val = 165000; + else + *val = 100000; + return IIO_VAL_FRACTIONAL; + case IIO_CHAN_INFO_OFFSET: + *val = -15887; + *val2 = 515151; + return IIO_VAL_INT_PLUS_MICRO; + default: + return -EINVAL; + } +} + +static int hdc2010_write_raw(struct iio_dev *indio_dev, + struct iio_chan_spec const *chan, + int val, int val2, long mask) +{ + struct hdc2010_data *data = iio_priv(indio_dev); + int new, ret; + + switch (mask) { + case IIO_CHAN_INFO_RAW: + if (chan->type != IIO_CURRENT || val2 != 0) + return -EINVAL; + + switch (val) { + case 1: + new = HDC2010_HEATER_EN; + break; + case 0: + new = 0; + break; + default: + return -EINVAL; + } + + mutex_lock(&data->lock); + ret = hdc2010_update_drdy_config(data, HDC2010_HEATER_EN, new); + mutex_unlock(&data->lock); + return ret; + default: + return -EINVAL; + } +} + +static const struct iio_info hdc2010_info = { + .read_raw = hdc2010_read_raw, + .write_raw = hdc2010_write_raw, + .attrs = &hdc2010_attribute_group, +}; + +static int hdc2010_probe(struct i2c_client *client, + const struct i2c_device_id *id) +{ + struct iio_dev *indio_dev; + struct hdc2010_data *data; + u8 tmp; + int ret; + + if (!i2c_check_functionality(client->adapter, + I2C_FUNC_SMBUS_WORD_DATA | I2C_FUNC_SMBUS_BYTE | I2C_FUNC_I2C)) + return -EOPNOTSUPP; + + indio_dev = devm_iio_device_alloc(&client->dev, sizeof(*data)); + if (!indio_dev) + return -ENOMEM; + + data = iio_priv(indio_dev); + i2c_set_clientdata(client, indio_dev); + data->client = client; + mutex_init(&data->lock); + + indio_dev->dev.parent = &client->dev; + /* + * As DEVICE ID register does not differentiate between + * HDC2010 and HDC2080, we have the name hardcoded + */ + indio_dev->name = "hdc2010"; + indio_dev->modes = INDIO_DIRECT_MODE; + indio_dev->info = &hdc2010_info; + + indio_dev->channels = hdc2010_channels; + indio_dev->num_channels = ARRAY_SIZE(hdc2010_channels); + + /* Enable Automatic Measurement Mode at 5Hz */ + ret = hdc2010_update_drdy_config(data, HDC2010_AMM, HDC2010_AMM); + if (ret) + return ret; + + /* + * We enable both temp and humidity measurement. + * However the measurement won't start even in AMM until triggered. + */ + tmp = (data->measurement_config & ~HDC2010_MEAS_CONF) | + HDC2010_MEAS_TRIG; + + ret = i2c_smbus_write_byte_data(client, HDC2010_REG_MEASUREMENT_CONF, tmp); + if (ret) { + dev_warn(&client->dev, "Unable to set up measurement\n"); + if (hdc2010_update_drdy_config(data, HDC2010_AMM, 0)) + dev_warn(&client->dev, "Unable to restore default AMM\n"); + return ret; + }; + + data->measurement_config = tmp; + + return iio_device_register(indio_dev); +} + +static int hdc2010_remove(struct i2c_client *client) +{ + struct iio_dev *indio_dev = i2c_get_clientdata(client); + struct hdc2010_data *data = iio_priv(indio_dev); + + iio_device_unregister(indio_dev); + + /* Disable Automatic Measurement Mode */ + if (hdc2010_update_drdy_config(data, HDC2010_AMM, 0)) + dev_warn(&client->dev, "Unable to restore default AMM\n"); + + return 0; +} + +static const struct i2c_device_id hdc2010_id[] = { + { "hdc2010" }, + { "hdc2080" }, + { } +}; +MODULE_DEVICE_TABLE(i2c, hdc2010_id); + +static const struct of_device_id hdc2010_dt_ids[] = { + { .compatible = "ti,hdc2010" }, + { .compatible = "ti,hdc2080" }, + { } +}; +MODULE_DEVICE_TABLE(of, hdc2010_dt_ids); + +static struct i2c_driver hdc2010_driver = { + .driver = { + .name = "hdc2010", + .of_match_table = hdc2010_dt_ids, + }, + .probe = hdc2010_probe, + .remove = hdc2010_remove, + .id_table = hdc2010_id, +}; +module_i2c_driver(hdc2010_driver); + +MODULE_AUTHOR("Eugene Zaikonnikov "); +MODULE_DESCRIPTION("TI HDC2010 humidity and temperature sensor driver"); +MODULE_LICENSE("GPL"); diff -uprN -X linux-5.3.8/Documentation/dontdiff linux-5.3.8/drivers/iio/humidity/Kconfig linux-5.3.8_hdc2010/drivers/iio/humidity/Kconfig --- linux-5.3.8/drivers/iio/humidity/Kconfig 2019-10-29 09:22:48.000000000 +0100 +++ linux-5.3.8_hdc2010/drivers/iio/humidity/Kconfig 2019-11-28 14:31:27.794242693 +0100 @@ -38,6 +38,16 @@ config HDC100X To compile this driver as a module, choose M here: the module will be called hdc100x. +config HDC2010 + tristate "TI HDC2010 relative humidity and temperature sensor" + depends on I2C + help + Say yes here to build support for the Texas Instruments + HDC2010 and HDC2080 relative humidity and temperature sensors. + + To compile this driver as a module, choose M here: the module + will be called hdc2010. + config HID_SENSOR_HUMIDITY tristate "HID Environmental humidity sensor" depends on HID_SENSOR_HUB diff -uprN -X linux-5.3.8/Documentation/dontdiff linux-5.3.8/drivers/iio/humidity/Makefile linux-5.3.8_hdc2010/drivers/iio/humidity/Makefile --- linux-5.3.8/drivers/iio/humidity/Makefile 2019-10-29 09:22:48.000000000 +0100 +++ linux-5.3.8_hdc2010/drivers/iio/humidity/Makefile 2019-11-28 14:30:40.609892061 +0100 @@ -6,6 +6,7 @@ obj-$(CONFIG_AM2315) += am2315.o obj-$(CONFIG_DHT11) += dht11.o obj-$(CONFIG_HDC100X) += hdc100x.o +obj-$(CONFIG_HDC2010) += hdc2010.o obj-$(CONFIG_HID_SENSOR_HUMIDITY) += hid-sensor-humidity.o hts221-y := hts221_core.o \