diff mbox

[PATCHv6,3/5] Input: edt-ft5x06: Adjust delays to conform datasheet

Message ID 1395673870-29435-4-git-send-email-LW@KARO-electronics.de (mailing list archive)
State New, archived
Headers show

Commit Message

Lothar Waßmann March 24, 2014, 3:11 p.m. UTC
The FT5x06 datasheet specifies a minimum reset width of 5ms and a
delay between deassertion of reset and start of reporting of 300ms.
Adjust the delays to conform to the datasheet.

With the original delays I sometimes experienced communication
timeouts when initializing the controller.

Signed-off-by: Lothar Waßmann <LW@KARO-electronics.de>
---
 drivers/input/touchscreen/edt-ft5x06.c |    6 +++---
 1 file changed, 3 insertions(+), 3 deletions(-)
diff mbox

Patch

diff --git a/drivers/input/touchscreen/edt-ft5x06.c b/drivers/input/touchscreen/edt-ft5x06.c
index 04d0665..cc5185a 100644
--- a/drivers/input/touchscreen/edt-ft5x06.c
+++ b/drivers/input/touchscreen/edt-ft5x06.c
@@ -635,7 +635,7 @@  static int edt_ft5x06_ts_reset(struct i2c_client *client,
 			return error;
 		}
 
-		mdelay(5);
+		msleep(5);
 		gpio_set_value(tsdata->wake_pin, 1);
 	}
 	if (gpio_is_valid(tsdata->reset_pin)) {
@@ -650,9 +650,9 @@  static int edt_ft5x06_ts_reset(struct i2c_client *client,
 			return error;
 		}
 
-		mdelay(50);
+		msleep(5);
 		gpio_set_value(tsdata->reset_pin, 1);
-		mdelay(100);
+		msleep(300);
 	}
 
 	return 0;