Message ID | 1454455218-13004-2-git-send-email-stefan@agner.ch (mailing list archive) |
---|---|
State | Accepted |
Headers | show |
On 02/03/2016 12:20 AM, Stefan Agner wrote: > The X/Y position measurements read from the controller are interpreted > wrong. The first measurement X+ contains the Y position, and the second > measurement Y+ the X position (see also Table 11 Register Table in the > data sheet). > > The problem is already known and a swap option has been introduced: > commit 6680884a4420 ("Input: ad7879 - add option to correct xy axis") > > However, the meaning of the new boolean is inverted since the underlying > values are already swapped. Let ts->swap_xy set to true actually be the > swapped configuration of the two axis. > > Signed-off-by: Stefan Agner <stefan@agner.ch> Acked-by: Michael Hennerich <michael.hennerich@analog.com> > --- > Changes since v2: > - (none) > Changes since v1: > - Keep axis swapped by default when using platform data > > drivers/input/touchscreen/ad7879.c | 8 +++++--- > 1 file changed, 5 insertions(+), 3 deletions(-) > > diff --git a/drivers/input/touchscreen/ad7879.c b/drivers/input/touchscreen/ad7879.c > index 93b8ea2..abd0220 100644 > --- a/drivers/input/touchscreen/ad7879.c > +++ b/drivers/input/touchscreen/ad7879.c > @@ -94,8 +94,8 @@ > #define AD7879_TEMP_BIT (1<<1) > > enum { > - AD7879_SEQ_XPOS = 0, > - AD7879_SEQ_YPOS = 1, > + AD7879_SEQ_YPOS = 0, > + AD7879_SEQ_XPOS = 1, > AD7879_SEQ_Z1 = 2, > AD7879_SEQ_Z2 = 3, > AD7879_NR_SENSE = 4, > @@ -517,7 +517,9 @@ struct ad7879 *ad7879_probe(struct device *dev, u8 devid, unsigned int irq, > ts->dev = dev; > ts->input = input_dev; > ts->irq = irq; > - ts->swap_xy = pdata->swap_xy; > + > + /* Use swapped axis by default (backward compatibility) */ > + ts->swap_xy = !pdata->swap_xy; > > setup_timer(&ts->timer, ad7879_timer, (unsigned long) ts); > >
diff --git a/drivers/input/touchscreen/ad7879.c b/drivers/input/touchscreen/ad7879.c index 93b8ea2..abd0220 100644 --- a/drivers/input/touchscreen/ad7879.c +++ b/drivers/input/touchscreen/ad7879.c @@ -94,8 +94,8 @@ #define AD7879_TEMP_BIT (1<<1) enum { - AD7879_SEQ_XPOS = 0, - AD7879_SEQ_YPOS = 1, + AD7879_SEQ_YPOS = 0, + AD7879_SEQ_XPOS = 1, AD7879_SEQ_Z1 = 2, AD7879_SEQ_Z2 = 3, AD7879_NR_SENSE = 4, @@ -517,7 +517,9 @@ struct ad7879 *ad7879_probe(struct device *dev, u8 devid, unsigned int irq, ts->dev = dev; ts->input = input_dev; ts->irq = irq; - ts->swap_xy = pdata->swap_xy; + + /* Use swapped axis by default (backward compatibility) */ + ts->swap_xy = !pdata->swap_xy; setup_timer(&ts->timer, ad7879_timer, (unsigned long) ts);
The X/Y position measurements read from the controller are interpreted wrong. The first measurement X+ contains the Y position, and the second measurement Y+ the X position (see also Table 11 Register Table in the data sheet). The problem is already known and a swap option has been introduced: commit 6680884a4420 ("Input: ad7879 - add option to correct xy axis") However, the meaning of the new boolean is inverted since the underlying values are already swapped. Let ts->swap_xy set to true actually be the swapped configuration of the two axis. Signed-off-by: Stefan Agner <stefan@agner.ch> --- Changes since v2: - (none) Changes since v1: - Keep axis swapped by default when using platform data drivers/input/touchscreen/ad7879.c | 8 +++++--- 1 file changed, 5 insertions(+), 3 deletions(-)