diff mbox series

[v4,4/7] arm64: dts: mt8183: Configure CPU cooling

Message ID 20200323121537.22697-5-michael.kao@mediatek.com (mailing list archive)
State New, archived
Headers show
Series Add Mediatek thermal dirver and dtsi | expand

Commit Message

Michael Kao March 23, 2020, 12:15 p.m. UTC
From: Matthias Kaehlcke <mka@chromium.org>

Add two passive trip points at 68°C and 80°C for the CPU temperature.

Signed-off-by: Matthias Kaehlcke <mka@chromium.org>
Signed-off-by: Michael Kao <michael.kao@mediatek.com>
---
 arch/arm64/boot/dts/mediatek/mt8183.dtsi | 55 ++++++++++++++++++++++++
 1 file changed, 55 insertions(+)
diff mbox series

Patch

diff --git a/arch/arm64/boot/dts/mediatek/mt8183.dtsi b/arch/arm64/boot/dts/mediatek/mt8183.dtsi
index 182fa6264e0d..59ab2957d85d 100644
--- a/arch/arm64/boot/dts/mediatek/mt8183.dtsi
+++ b/arch/arm64/boot/dts/mediatek/mt8183.dtsi
@@ -675,6 +675,61 @@ 
 				polling-delay = <500>;
 				thermal-sensors = <&thermal 0>;
 				sustainable-power = <5000>;
+
+				trips {
+					threshold: trip-point@0 {
+						temperature = <68000>;
+						hysteresis = <2000>;
+						type = "passive";
+					};
+
+					target: trip-point@1 {
+						temperature = <80000>;
+						hysteresis = <2000>;
+						type = "passive";
+					};
+
+					cpu_crit: cpu-crit {
+						temperature = <115000>;
+						hysteresis = <2000>;
+						type = "critical";
+					};
+				};
+
+				cooling-maps {
+					map0 {
+						trip = <&target>;
+						cooling-device = <&cpu0
+							THERMAL_NO_LIMIT
+							THERMAL_NO_LIMIT>,
+								 <&cpu1
+							THERMAL_NO_LIMIT
+							THERMAL_NO_LIMIT>,
+								 <&cpu2
+							THERMAL_NO_LIMIT
+							THERMAL_NO_LIMIT>,
+								 <&cpu3
+							THERMAL_NO_LIMIT
+							THERMAL_NO_LIMIT>;
+						contribution = <3072>;
+					};
+					map1 {
+						trip = <&target>;
+						cooling-device = <&cpu4
+							THERMAL_NO_LIMIT
+							THERMAL_NO_LIMIT>,
+								 <&cpu5
+							THERMAL_NO_LIMIT
+							THERMAL_NO_LIMIT>,
+								 <&cpu6
+							THERMAL_NO_LIMIT
+							THERMAL_NO_LIMIT>,
+								 <&cpu7
+							THERMAL_NO_LIMIT
+							THERMAL_NO_LIMIT>;
+						contribution = <1024>;
+					};
+				};
 			};
 
 			/* The tzts1 ~ tzts6 don't need to polling */