Hi Roger, On Tuesday 02 June 2015 02:40 PM, Roger Quadros wrote: > This register is required to be passed to the SATA PHY driver > to workaround errata i783 (SATA Lockup After SATA DPLL Unlock/Relock). > > Signed-off-by: Roger Quadros <rogerq@ti.com> > Signed-off-by: Sekhar Nori <nsekhar@ti.com> > --- > arch/arm/boot/dts/dra7.dtsi | 1 + > 1 file changed, 1 insertion(+) > > diff --git a/arch/arm/boot/dts/dra7.dtsi b/arch/arm/boot/dts/dra7.dtsi > index f03a091..260f300 100644 > --- a/arch/arm/boot/dts/dra7.dtsi > +++ b/arch/arm/boot/dts/dra7.dtsi > @@ -1135,6 +1135,7 @@ > ctrl-module = <&omap_control_sata>; > clocks = <&sys_clkin1>, <&sata_ref_clk>; > clock-names = "sysclk", "refclk"; > + syscon-pllreset = <&dra7_ctrl_core 0x3fc>; I think all users of syscon should be made child node of scm_conf. Tony and Tero, is that right? If so, then we might have to modify the driver too. Cheers Kishon -- To unsubscribe from this list: send the line "unsubscribe linux-omap" in the body of a message to majordomo@vger.kernel.org More majordomo info at http://vger.kernel.org/majordomo-info.html
* Kishon Vijay Abraham I <kishon@ti.com> [150715 04:24]: > Hi Roger, > > On Tuesday 02 June 2015 02:40 PM, Roger Quadros wrote: > > This register is required to be passed to the SATA PHY driver > > to workaround errata i783 (SATA Lockup After SATA DPLL Unlock/Relock). > > > > Signed-off-by: Roger Quadros <rogerq@ti.com> > > Signed-off-by: Sekhar Nori <nsekhar@ti.com> > > --- > > arch/arm/boot/dts/dra7.dtsi | 1 + > > 1 file changed, 1 insertion(+) > > > > diff --git a/arch/arm/boot/dts/dra7.dtsi b/arch/arm/boot/dts/dra7.dtsi > > index f03a091..260f300 100644 > > --- a/arch/arm/boot/dts/dra7.dtsi > > +++ b/arch/arm/boot/dts/dra7.dtsi > > @@ -1135,6 +1135,7 @@ > > ctrl-module = <&omap_control_sata>; > > clocks = <&sys_clkin1>, <&sata_ref_clk>; > > clock-names = "sysclk", "refclk"; > > + syscon-pllreset = <&dra7_ctrl_core 0x3fc>; > > I think all users of syscon should be made child node of scm_conf. Tony and > Tero, is that right? > > If so, then we might have to modify the driver too. Yeah there should not be much need to use syscon outside scm_conf area and for I2C devices. If there's some other misc register area in dra7 in addition to scm_conf then it might make sense to use it. But in general, for the SCM registers, just a normal loadable kernel driver module doing of_ioremap on a dedicated range of registers is always a better option :) Regrds, Tony -- To unsubscribe from this list: send the line "unsubscribe linux-omap" in the body of a message to majordomo@vger.kernel.org More majordomo info at http://vger.kernel.org/majordomo-info.html
Hi, On 15/07/15 15:07, Tony Lindgren wrote: > * Kishon Vijay Abraham I <kishon@ti.com> [150715 04:24]: >> Hi Roger, >> >> On Tuesday 02 June 2015 02:40 PM, Roger Quadros wrote: >>> This register is required to be passed to the SATA PHY driver >>> to workaround errata i783 (SATA Lockup After SATA DPLL Unlock/Relock). >>> >>> Signed-off-by: Roger Quadros <rogerq@ti.com> >>> Signed-off-by: Sekhar Nori <nsekhar@ti.com> >>> --- >>> arch/arm/boot/dts/dra7.dtsi | 1 + >>> 1 file changed, 1 insertion(+) >>> >>> diff --git a/arch/arm/boot/dts/dra7.dtsi b/arch/arm/boot/dts/dra7.dtsi >>> index f03a091..260f300 100644 >>> --- a/arch/arm/boot/dts/dra7.dtsi >>> +++ b/arch/arm/boot/dts/dra7.dtsi >>> @@ -1135,6 +1135,7 @@ >>> ctrl-module = <&omap_control_sata>; >>> clocks = <&sys_clkin1>, <&sata_ref_clk>; >>> clock-names = "sysclk", "refclk"; >>> + syscon-pllreset = <&dra7_ctrl_core 0x3fc>; >> >> I think all users of syscon should be made child node of scm_conf. Tony and >> Tero, is that right? It can't be child of scm_conf as the address is outside it's range. Looks like I have to add a new child to scm node that maps beyond the dra7_pmx_core padconf address range. >> >> If so, then we might have to modify the driver too. > > Yeah there should not be much need to use syscon outside scm_conf > area and for I2C devices. If there's some other misc register area > in dra7 in addition to scm_conf then it might make sense to use it. > > But in general, for the SCM registers, just a normal loadable kernel > driver module doing of_ioremap on a dedicated range of registers is > always a better option :) > Lets take for example this register CTRL_CORE_SMA_SW_0. It has the SATA PLL_SOFT_RESET bit, EMIF1/2 gating control bits and ISOLATE bit. I don't see this fitting in any driver except the syscon approach. cheers, -roger -- To unsubscribe from this list: send the line "unsubscribe linux-omap" in the body of a message to majordomo@vger.kernel.org More majordomo info at http://vger.kernel.org/majordomo-info.html
On 07/15/2015 04:47 PM, Roger Quadros wrote: > Hi, > > On 15/07/15 15:07, Tony Lindgren wrote: >> * Kishon Vijay Abraham I <kishon@ti.com> [150715 04:24]: >>> Hi Roger, >>> >>> On Tuesday 02 June 2015 02:40 PM, Roger Quadros wrote: >>>> This register is required to be passed to the SATA PHY driver >>>> to workaround errata i783 (SATA Lockup After SATA DPLL Unlock/Relock). >>>> >>>> Signed-off-by: Roger Quadros <rogerq@ti.com> >>>> Signed-off-by: Sekhar Nori <nsekhar@ti.com> >>>> --- >>>> arch/arm/boot/dts/dra7.dtsi | 1 + >>>> 1 file changed, 1 insertion(+) >>>> >>>> diff --git a/arch/arm/boot/dts/dra7.dtsi b/arch/arm/boot/dts/dra7.dtsi >>>> index f03a091..260f300 100644 >>>> --- a/arch/arm/boot/dts/dra7.dtsi >>>> +++ b/arch/arm/boot/dts/dra7.dtsi >>>> @@ -1135,6 +1135,7 @@ >>>> ctrl-module = <&omap_control_sata>; >>>> clocks = <&sys_clkin1>, <&sata_ref_clk>; >>>> clock-names = "sysclk", "refclk"; >>>> + syscon-pllreset = <&dra7_ctrl_core 0x3fc>; >>> >>> I think all users of syscon should be made child node of scm_conf. Tony and >>> Tero, is that right? > > It can't be child of scm_conf as the address is outside it's range. > Looks like I have to add a new child to scm node that maps beyond > the dra7_pmx_core padconf address range. > >>> >>> If so, then we might have to modify the driver too. >> >> Yeah there should not be much need to use syscon outside scm_conf >> area and for I2C devices. If there's some other misc register area >> in dra7 in addition to scm_conf then it might make sense to use it. >> >> But in general, for the SCM registers, just a normal loadable kernel >> driver module doing of_ioremap on a dedicated range of registers is >> always a better option :) >> > > Lets take for example this register CTRL_CORE_SMA_SW_0. > It has the SATA PLL_SOFT_RESET bit, EMIF1/2 gating control bits > and ISOLATE bit. > > I don't see this fitting in any driver except the syscon approach. > > cheers, > -roger > Yea I think scm_conf can generally contain lots of weird registers that can have multiple users / use-cases. This is the junk-yard of SoC features the designers had no idea where to put them; so they put it under scm_conf. I'd say in some cases we are probably forced to map to it from other drivers, this is one of the reasons it is a syscon map in the first place, and generally speaking, they should not be children of scm_conf in the DT layout. You could probably add a "dummy" node under scm_conf which maps to the scm register, and which you would refer to from the sata driver. -Tero -- To unsubscribe from this list: send the line "unsubscribe linux-omap" in the body of a message to majordomo@vger.kernel.org More majordomo info at http://vger.kernel.org/majordomo-info.html
diff --git a/arch/arm/boot/dts/dra7.dtsi b/arch/arm/boot/dts/dra7.dtsi index f03a091..260f300 100644 --- a/arch/arm/boot/dts/dra7.dtsi +++ b/arch/arm/boot/dts/dra7.dtsi @@ -1135,6 +1135,7 @@ ctrl-module = <&omap_control_sata>; clocks = <&sys_clkin1>, <&sata_ref_clk>; clock-names = "sysclk", "refclk"; + syscon-pllreset = <&dra7_ctrl_core 0x3fc>; #phy-cells = <0>; };