Message ID | 20170504001532.10585-5-tony@atomide.com (mailing list archive) |
---|---|
State | New, archived |
Headers | show |
diff --git a/drivers/power/supply/cpcap-charger.c b/drivers/power/supply/cpcap-charger.c --- a/drivers/power/supply/cpcap-charger.c +++ b/drivers/power/supply/cpcap-charger.c @@ -470,8 +470,7 @@ static void cpcap_usb_detect(struct work_struct *work) error = cpcap_charger_set_state(ddata, CPCAP_REG_CRM_VCHRG_4V35, - max_current, - CPCAP_REG_CRM_TR_0A72); + max_current, 0); if (error) goto out_err; } else {
Android does not seem to set the trickle charger bits, and these seem to be only used by the bootloader when bringing up a completely discharged battery. So let's keep the trickle charging bits disabled and avoid misconfiguring the hardware. Fixes: 0c9888e3c192 ("power: supply: cpcap-charger: Add minimal CPCAP PMIC battery charger") Cc: Marcel Partap <mpartap@gmx.net> Cc: Michael Scott <michael.scott@linaro.org> Signed-off-by: Tony Lindgren <tony@atomide.com> --- drivers/power/supply/cpcap-charger.c | 3 +-- 1 file changed, 1 insertion(+), 2 deletions(-)