diff mbox series

[10/12] ARM: dts: dra7: Use clksel binding for CM_CLKSEL_DPLL_PER

Message ID 20240327073856.21517-11-tony@atomide.com (mailing list archive)
State New
Headers show
Series Use clksel for more clocks for dra7 | expand

Commit Message

Tony Lindgren March 27, 2024, 7:38 a.m. UTC
With the clkcsel binding we can drop the custom ti,bit-shift devicetree
property in favor of the standard reg property and reduce the number of
clocks to update for the make W-1 dtbs warnings.

Let's also add a comment for the clocksel clock that matches the
documentation.

Signed-off-by: Tony Lindgren <tony@atomide.com>
---
 arch/arm/boot/dts/ti/omap/dra7xx-clocks.dtsi | 22 +++++++++++++-------
 1 file changed, 15 insertions(+), 7 deletions(-)
diff mbox series

Patch

diff --git a/arch/arm/boot/dts/ti/omap/dra7xx-clocks.dtsi b/arch/arm/boot/dts/ti/omap/dra7xx-clocks.dtsi
--- a/arch/arm/boot/dts/ti/omap/dra7xx-clocks.dtsi
+++ b/arch/arm/boot/dts/ti/omap/dra7xx-clocks.dtsi
@@ -1399,13 +1399,21 @@  apll_pcie_m2_ck: clock-apll-pcie-m2 {
 		clock-div = <1>;
 	};
 
-	dpll_per_byp_mux: clock-dpll-per-byp-mux-23@14c {
-		#clock-cells = <0>;
-		compatible = "ti,mux-clock";
-		clock-output-names = "dpll_per_byp_mux";
-		clocks = <&sys_clkin1>, <&per_dpll_hs_clk_div>;
-		ti,bit-shift = <23>;
-		reg = <0x014c>;
+	/* CM_CLKSEL_DPLL_PER */
+	clock@14c {
+		compatible = "ti,clksel";
+		reg = <0x14c>;
+		#clock-cells = <2>;
+		#address-cells = <1>;
+		#size-cells = <0>;
+
+		dpll_per_byp_mux: clock@23 {
+			reg = <23>;
+			compatible = "ti,mux-clock";
+			clock-output-names = "dpll_per_byp_mux";
+			clocks = <&sys_clkin1>, <&per_dpll_hs_clk_div>;
+			#clock-cells = <0>;
+		};
 	};
 
 	dpll_per_ck: clock@140 {