mbox series

[v5,0/5] power: supply: MAX17040: Add IRQ for low level and alert SOC changes

Message ID 20191105054218.29826-1-matheus@castello.eng.br (mailing list archive)
Headers show
Series power: supply: MAX17040: Add IRQ for low level and alert SOC changes | expand

Message

Matheus Castello Nov. 5, 2019, 5:42 a.m. UTC
This series add IRQ handler for low level SOC alert, define a devicetree
binding attribute to configure the alert level threshold and check for
changes in SOC and power supply status for send uevents.

Max17043/17044 have a pin for alert host about low level state of charge and
this alert can be configured in a threshold from 1% up to 32% of SOC.

Tested on Toradex Colibri iMX7D, with a SparkFun Lipo Fuel Gauge module
based on MAXIM MAX17043.

Thanks Krzysztof for your time reviewing it. Let me know what you think about
the fixes.

Changes since v4:
(Suggested by Krzysztof Kozlowski)
- Fix code style and alignment issues
- Keep IRQF_TRIGGER_FALLING | IRQF_ONESHOT instead client->flags

(Suggested by Rob Herring)
- Add reference to the MFD description
- Fix the dt-bindings commit description

Matheus Castello (5):
  power: supply: max17040: Add IRQ handler for low SOC alert
  dt-bindings: power: supply: Max17040: Add DT bindings for max17040
    fuel gauge
  devicetree: mfd: max14577: Add reference to max14040_battery.txt
    descriptions
  power: supply: max17040: Config alert SOC low level threshold from FDT
  power: supply: max17040: Send uevent in SOC and status change

 .../devicetree/bindings/mfd/max14577.txt      |   2 +
 .../power/supply/max17040_battery.txt         |  33 ++++
 drivers/power/supply/max17040_battery.c       | 142 +++++++++++++++++-
 3 files changed, 172 insertions(+), 5 deletions(-)
 create mode 100644 Documentation/devicetree/bindings/power/supply/max17040_battery.txt

--
2.24.0.rc2