diff --git a/drivers/thermal/int3403_thermal.c b/drivers/thermal/int3403_thermal.c index 1301681..e93f025 100644 --- a/drivers/thermal/int3403_thermal.c +++ b/drivers/thermal/int3403_thermal.c @@ -62,7 +62,13 @@ static int sys_get_trip_hyst(struct thermal_zone_device *tzone, if (ACPI_FAILURE(status)) return -EIO; - *temp = DECI_KELVIN_TO_MILLI_CELSIUS(hyst, KELVIN_OFFSET); + /* + * Thermal hysteresis represents a temperature difference. + * Kelvin and Celsius have same degree size. So the + * conversion here between tenths of degree Kelvin unit + * and Milli-Celsius unit is just to multiply 100. + */ + *temp = hyst * 100; return 0; }