[v3,11/13] drivers: sh: Disable PM runtime for multi-platform r8a7740 with genpd

Message ID 1411662520-22795-12-git-send-email-geert+renesas@glider.be (mailing list archive)
State Not Applicable, archived
Headers show

Commit Message

Geert Uytterhoeven Sept. 25, 2014, 4:28 p.m. UTC
If the default PM domain using PM_CLK is used for PM runtime, the real PM
domain(s) cannot be registered from DT later.

Hence do not enable it when running a multi-platform kernel with genpd
support on an r8a7740. The R-Mobile PM domain driver will take care of
PM runtime management of the module clocks.

The default PM domain is still needed for:
  - platforms without genpd support,
  - the legacy (non-DT) case, where genpd may take over later, except
    for the C5 "always on" PM domain.

Signed-off-by: Geert Uytterhoeven <geert+renesas@glider.be>
---
v3:
  - Reword
v2:
  - New

 drivers/sh/pm_runtime.c | 2 ++
 1 file changed, 2 insertions(+)
diff mbox

Patch

diff --git a/drivers/sh/pm_runtime.c b/drivers/sh/pm_runtime.c
index fe2c2d595f599b2f..85cc89fd3e7d7cb7 100644
--- a/drivers/sh/pm_runtime.c
+++ b/drivers/sh/pm_runtime.c
@@ -81,7 +81,9 @@  static int __init sh_pm_runtime_init(void)
 		if (!of_machine_is_compatible("renesas,emev2") &&
 		    !of_machine_is_compatible("renesas,r7s72100") &&
 		    !of_machine_is_compatible("renesas,r8a73a4") &&
+#ifndef CONFIG_PM_GENERIC_DOMAINS_OF
 		    !of_machine_is_compatible("renesas,r8a7740") &&
+#endif
 		    !of_machine_is_compatible("renesas,r8a7778") &&
 		    !of_machine_is_compatible("renesas,r8a7779") &&
 		    !of_machine_is_compatible("renesas,r8a7790") &&