Message ID | 1443196460-26156-2-git-send-email-dannenberg@ti.com (mailing list archive) |
---|---|
State | Not Applicable, archived |
Headers | show |
W dniu 26.09.2015 o 00:54, Andreas Dannenberg pisze: > Extend the bq24257 charger's device tree documentation to cover the > bq24250 and bq24251 devices as well feature additions. > > Signed-off-by: Andreas Dannenberg <dannenberg@ti.com> > --- > .../devicetree/bindings/power/bq24257.txt | 53 ++++++++++++++++++++-- > 1 file changed, 48 insertions(+), 5 deletions(-) > > diff --git a/Documentation/devicetree/bindings/power/bq24257.txt b/Documentation/devicetree/bindings/power/bq24257.txt > index 5c9d394..6c376ef 100644 > --- a/Documentation/devicetree/bindings/power/bq24257.txt > +++ b/Documentation/devicetree/bindings/power/bq24257.txt > @@ -1,21 +1,64 @@ > -Binding for TI bq24257 Li-Ion Charger > +Binding for TI bq24250/bq24251/bq24257 Li-Ion Charger > > Required properties: > - compatible: Should contain one of the following: > + * "ti,bq24250" > + * "ti,bq24251" > * "ti,bq24257" > -- reg: integer, i2c address of the device. > +- reg: integer, i2c address of the device. > +- interrupt-parent: Should be the phandle for the interrupt controller. Use in > + conjunction with "interrupts". > +- interrupts: Interrupt mapping for GPIO IRQ (configure for both edges). Use in > + conjunction with "interrupt-parent". > - ti,battery-regulation-voltage: integer, maximum charging voltage in uV. > -- ti,charge-current: integer, maximum charging current in uA. > -- ti,termination-current: integer, charge will be terminated when current in > - constant-voltage phase drops below this value (in uA). > +- ti,charge-current: integer, maximum charging current in uA. > +- ti,termination-current: integer, charge will be terminated when current in > + constant-voltage phase drops below this value (in uA). > + > +Optional properties: > +- pg-gpios: GPIO used for connecting the bq2425x device PG (Power Good) pin. > + This pin is not available on all devices however it should be used if > + possible as this is the recommended way to obtain the charger's input PG > + state. If this pin is not specified a software-based approach for PG > + detection is used. > +- ti,current-limit: The maximum current to be drawn from the charger's input > + (in uA). If this property is not specified a USB D+/D- signal based charger > + type detection is used (if available) and the input limit current is set > + accordingly. If the D+/D- based detection is not available on a given device > + a default of 500,000 is used (=500mA). > +- ti,ovp-voltage: Configures the over voltage protection voltage (in uV). If > + not specified a default of 6,5000,000 (=6.5V) is used. > +- ti,in-dpm-voltage: Configures the threshold input voltage for the dynamic > + power path management (in uV). If not specified a default of 4,360,000 > + (=4.36V) is used. > > Example: > > bq24257 { > compatible = "ti,bq24257"; > reg = <0x6a>; > + interrupt-parent = <&gpio1>; > + interrupts = <16 IRQ_TYPE_EDGE_BOTH>; > + > + pg-gpios = <&gpio1 28 GPIO_ACTIVE_HIGH>; > > ti,battery-regulation-voltage = <4200000>; > ti,charge-current = <1000000>; > ti,termination-current = <50000>; > }; > + > +Example: > + > +bq24250 { > + compatible = "ti,bq24250"; > + reg = <0x6a>; > + interrupt-parent = <&gpio1>; > + interrupts = <16 IRQ_TYPE_EDGE_BOTH>; > + > + ti,battery-regulation-voltage = <4200000>; > + ti,charge-current = <500000>; > + ti,termination-current = <50000>; > + ti,current-limit = <900000>; > + ti,ovp-voltage = <9500000>; > + ti,in-dpm-voltage = <4440000>; > +}; Once again: Reviewed-by: Krzysztof Kozlowski <k.kozlowski@samsung.com> Best regards, Krzysztof -- To unsubscribe from this list: send the line "unsubscribe linux-pm" in the body of a message to majordomo@vger.kernel.org More majordomo info at http://vger.kernel.org/majordomo-info.html
Hi, On Fri, Sep 25, 2015 at 10:54:06AM -0500, Andreas Dannenberg wrote: > Extend the bq24257 charger's device tree documentation to cover the > bq24250 and bq24251 devices as well feature additions. > > [...] > > +- ti,current-limit: The maximum current to be drawn from the charger's input > + (in uA). If this property is not specified a USB D+/D- signal based charger > + type detection is used (if available) and the input limit current is set > + accordingly. If the D+/D- based detection is not available on a given device > + a default of 500,000 is used (=500mA). I think this wording is a bit better: - ti,current-limit: The maximum current to be drawn from the charger's input (in uA). If this property is not specified, the input limit current is set automatically using USB D+/D- signal based charger type detection. If the hardware does not support the D+/D- based detection, a default of 500,000 is used (=500mA) instead. -- Sebastian
diff --git a/Documentation/devicetree/bindings/power/bq24257.txt b/Documentation/devicetree/bindings/power/bq24257.txt index 5c9d394..6c376ef 100644 --- a/Documentation/devicetree/bindings/power/bq24257.txt +++ b/Documentation/devicetree/bindings/power/bq24257.txt @@ -1,21 +1,64 @@ -Binding for TI bq24257 Li-Ion Charger +Binding for TI bq24250/bq24251/bq24257 Li-Ion Charger Required properties: - compatible: Should contain one of the following: + * "ti,bq24250" + * "ti,bq24251" * "ti,bq24257" -- reg: integer, i2c address of the device. +- reg: integer, i2c address of the device. +- interrupt-parent: Should be the phandle for the interrupt controller. Use in + conjunction with "interrupts". +- interrupts: Interrupt mapping for GPIO IRQ (configure for both edges). Use in + conjunction with "interrupt-parent". - ti,battery-regulation-voltage: integer, maximum charging voltage in uV. -- ti,charge-current: integer, maximum charging current in uA. -- ti,termination-current: integer, charge will be terminated when current in - constant-voltage phase drops below this value (in uA). +- ti,charge-current: integer, maximum charging current in uA. +- ti,termination-current: integer, charge will be terminated when current in + constant-voltage phase drops below this value (in uA). + +Optional properties: +- pg-gpios: GPIO used for connecting the bq2425x device PG (Power Good) pin. + This pin is not available on all devices however it should be used if + possible as this is the recommended way to obtain the charger's input PG + state. If this pin is not specified a software-based approach for PG + detection is used. +- ti,current-limit: The maximum current to be drawn from the charger's input + (in uA). If this property is not specified a USB D+/D- signal based charger + type detection is used (if available) and the input limit current is set + accordingly. If the D+/D- based detection is not available on a given device + a default of 500,000 is used (=500mA). +- ti,ovp-voltage: Configures the over voltage protection voltage (in uV). If + not specified a default of 6,5000,000 (=6.5V) is used. +- ti,in-dpm-voltage: Configures the threshold input voltage for the dynamic + power path management (in uV). If not specified a default of 4,360,000 + (=4.36V) is used. Example: bq24257 { compatible = "ti,bq24257"; reg = <0x6a>; + interrupt-parent = <&gpio1>; + interrupts = <16 IRQ_TYPE_EDGE_BOTH>; + + pg-gpios = <&gpio1 28 GPIO_ACTIVE_HIGH>; ti,battery-regulation-voltage = <4200000>; ti,charge-current = <1000000>; ti,termination-current = <50000>; }; + +Example: + +bq24250 { + compatible = "ti,bq24250"; + reg = <0x6a>; + interrupt-parent = <&gpio1>; + interrupts = <16 IRQ_TYPE_EDGE_BOTH>; + + ti,battery-regulation-voltage = <4200000>; + ti,charge-current = <500000>; + ti,termination-current = <50000>; + ti,current-limit = <900000>; + ti,ovp-voltage = <9500000>; + ti,in-dpm-voltage = <4440000>; +};
Extend the bq24257 charger's device tree documentation to cover the bq24250 and bq24251 devices as well feature additions. Signed-off-by: Andreas Dannenberg <dannenberg@ti.com> --- .../devicetree/bindings/power/bq24257.txt | 53 ++++++++++++++++++++-- 1 file changed, 48 insertions(+), 5 deletions(-)