Message ID | 20210311115735.1103-1-cxfcosmos@gmail.com (mailing list archive) |
---|---|
State | Not Applicable, archived |
Headers | show |
Series | Rectify spelling | expand |
Hi, On Thu, Mar 11, 2021 at 07:57:35PM +0800, Xiaofeng Cao wrote: > Change 'stanalone' to 'standalone' > Change 'mesaurement' to 'measurement' > Change 'nonvilatile' to 'nonvolatile' > Change 'unical' to 'unique' > Change 'unaccesable' to 'unaccessible' > Change 'correcpondent' to 'correspond' > > Signed-off-by: Xiaofeng Cao <caoxiaofeng@yulong.com> > --- Thanks, queued. Please improve your patch subjects in the future and use PATCHv2 instead of PATCH when sending a new version. -- Sebastian > drivers/power/supply/max1721x_battery.c | 14 +++++++------- > 1 file changed, 7 insertions(+), 7 deletions(-) > > diff --git a/drivers/power/supply/max1721x_battery.c b/drivers/power/supply/max1721x_battery.c > index 1b1a36f8e929..473e53cd2801 100644 > --- a/drivers/power/supply/max1721x_battery.c > +++ b/drivers/power/supply/max1721x_battery.c > @@ -1,6 +1,6 @@ > /* > * 1-Wire implementation for Maxim Semiconductor > - * MAX7211/MAX17215 stanalone fuel gauge chip > + * MAX7211/MAX17215 standalone fuel gauge chip > * > * Copyright (C) 2017 Radioavionica Corporation > * Author: Alex A. Mihaylov <minimumlaw@rambler.ru> > @@ -28,7 +28,7 @@ > /* Number of valid register addresses in W1 mode */ > #define MAX1721X_MAX_REG_NR 0x1EF > > -/* Factory settings (nonvilatile registers) (W1 specific) */ > +/* Factory settings (nonvolatile registers) (W1 specific) */ > #define MAX1721X_REG_NRSENSE 0x1CF /* RSense in 10^-5 Ohm */ > /* Strings */ > #define MAX1721X_REG_MFG_STR 0x1CC > @@ -105,7 +105,7 @@ static inline int max172xx_temperature_to_ps(unsigned int reg) > /* > * Calculating current registers resolution: > * > - * RSense stored in 10^-5 Ohm, so mesaurment voltage must be > + * RSense stored in 10^-5 Ohm, so measurement voltage must be > * in 10^-11 Volts for get current in uA. > * 16 bit current reg fullscale +/-51.2mV is 102400 uV. > * So: 102400 / 65535 * 10^5 = 156252 > @@ -137,7 +137,7 @@ static int max1721x_battery_get_property(struct power_supply *psy, > /* > * POWER_SUPPLY_PROP_PRESENT will always readable via > * sysfs interface. Value return 0 if battery not > - * present or unaccesable via W1. > + * present or unaccessible via W1. > */ > val->intval = > regmap_read(info->regmap, MAX172XX_REG_STATUS, > @@ -334,9 +334,9 @@ static int devm_w1_max1721x_add_device(struct w1_slave *sl) > > /* > * power_supply class battery name translated from W1 slave device > - * unical ID (look like 26-0123456789AB) to "max1721x-0123456789AB\0" > - * so, 26 (device family) correcpondent to max1721x devices. > - * Device name still unical for any numbers connected devices. > + * unique ID (look like 26-0123456789AB) to "max1721x-0123456789AB\0" > + * so, 26 (device family) correspond to max1721x devices. > + * Device name still unique for any number of connected devices. > */ > snprintf(info->name, sizeof(info->name), > "max1721x-%012X", (unsigned int)sl->reg_num.id); > -- > 2.25.1 >
diff --git a/drivers/power/supply/max1721x_battery.c b/drivers/power/supply/max1721x_battery.c index 1b1a36f8e929..473e53cd2801 100644 --- a/drivers/power/supply/max1721x_battery.c +++ b/drivers/power/supply/max1721x_battery.c @@ -1,6 +1,6 @@ /* * 1-Wire implementation for Maxim Semiconductor - * MAX7211/MAX17215 stanalone fuel gauge chip + * MAX7211/MAX17215 standalone fuel gauge chip * * Copyright (C) 2017 Radioavionica Corporation * Author: Alex A. Mihaylov <minimumlaw@rambler.ru> @@ -28,7 +28,7 @@ /* Number of valid register addresses in W1 mode */ #define MAX1721X_MAX_REG_NR 0x1EF -/* Factory settings (nonvilatile registers) (W1 specific) */ +/* Factory settings (nonvolatile registers) (W1 specific) */ #define MAX1721X_REG_NRSENSE 0x1CF /* RSense in 10^-5 Ohm */ /* Strings */ #define MAX1721X_REG_MFG_STR 0x1CC @@ -105,7 +105,7 @@ static inline int max172xx_temperature_to_ps(unsigned int reg) /* * Calculating current registers resolution: * - * RSense stored in 10^-5 Ohm, so mesaurment voltage must be + * RSense stored in 10^-5 Ohm, so measurement voltage must be * in 10^-11 Volts for get current in uA. * 16 bit current reg fullscale +/-51.2mV is 102400 uV. * So: 102400 / 65535 * 10^5 = 156252 @@ -137,7 +137,7 @@ static int max1721x_battery_get_property(struct power_supply *psy, /* * POWER_SUPPLY_PROP_PRESENT will always readable via * sysfs interface. Value return 0 if battery not - * present or unaccesable via W1. + * present or unaccessible via W1. */ val->intval = regmap_read(info->regmap, MAX172XX_REG_STATUS, @@ -334,9 +334,9 @@ static int devm_w1_max1721x_add_device(struct w1_slave *sl) /* * power_supply class battery name translated from W1 slave device - * unical ID (look like 26-0123456789AB) to "max1721x-0123456789AB\0" - * so, 26 (device family) correcpondent to max1721x devices. - * Device name still unical for any numbers connected devices. + * unique ID (look like 26-0123456789AB) to "max1721x-0123456789AB\0" + * so, 26 (device family) correspond to max1721x devices. + * Device name still unique for any number of connected devices. */ snprintf(info->name, sizeof(info->name), "max1721x-%012X", (unsigned int)sl->reg_num.id);
Change 'stanalone' to 'standalone' Change 'mesaurement' to 'measurement' Change 'nonvilatile' to 'nonvolatile' Change 'unical' to 'unique' Change 'unaccesable' to 'unaccessible' Change 'correcpondent' to 'correspond' Signed-off-by: Xiaofeng Cao <caoxiaofeng@yulong.com> --- drivers/power/supply/max1721x_battery.c | 14 +++++++------- 1 file changed, 7 insertions(+), 7 deletions(-)