@@ -3023,6 +3023,10 @@ static int ab8500_fg_bind(struct device *dev, struct device *master,
return -ENOMEM;
}
+ di->bat_cap.max_mah_design = di->bm->bi.charge_full_design_uah;
+ di->bat_cap.max_mah = di->bat_cap.max_mah_design;
+ di->vbat_nom_uv = di->bm->bi.voltage_max_design_uv;
+
/* Start the coulomb counter */
ab8500_fg_coulomb_counter(di, true);
/* Run the FG algorithm */
@@ -3082,10 +3086,6 @@ static int ab8500_fg_probe(struct platform_device *pdev)
psy_cfg.num_supplicants = ARRAY_SIZE(supply_interface);
psy_cfg.drv_data = di;
- di->bat_cap.max_mah_design = di->bm->bi.charge_full_design_uah;
- di->bat_cap.max_mah = di->bat_cap.max_mah_design;
- di->vbat_nom_uv = di->bm->bi.voltage_max_design_uv;
-
di->init_capacity = true;
ab8500_fg_charge_state_to(di, AB8500_FG_CHARGE_INIT);
We were assigning some battery data state in probe() but this is insecure as it depends on the proper probe order between the components: the charger must probe first so that the battery data is populated. Move the init to the bind() call which is certain to happen after the probe of the master and all components has happened. Signed-off-by: Linus Walleij <linus.walleij@linaro.org> --- drivers/power/supply/ab8500_fg.c | 8 ++++---- 1 file changed, 4 insertions(+), 4 deletions(-)