@@ -360,11 +360,8 @@ static int armada_select_channel(struct armada_thermal_priv *priv, int channel)
* we must absolutely wait for the sensor validity bit to ensure we read
* actual data.
*/
- if (armada_wait_sensor_validity(priv)) {
- dev_err(priv->dev,
- "Temperature sensor reading not valid\n");
+ if (armada_wait_sensor_validity(priv))
return -EIO;
- }
return 0;
}
@@ -402,11 +399,8 @@ static int armada_get_temp_legacy(struct thermal_zone_device *thermal,
int ret;
/* Valid check */
- if (!armada_is_valid(priv)) {
- dev_err(priv->dev,
- "Temperature sensor reading not valid\n");
+ if (!armada_is_valid(priv))
return -EIO;
- }
/* Do the actual reading */
ret = armada_read_sensor(priv, temp);
@@ -158,10 +158,8 @@ static int brcmstb_get_temp(struct thermal_zone_device *tz, int *temp)
val = __raw_readl(priv->tmon_base + AVS_TMON_STATUS);
- if (!(val & AVS_TMON_STATUS_valid_msk)) {
- dev_err(priv->dev, "reading not valid\n");
+ if (!(val & AVS_TMON_STATUS_valid_msk))
return -EIO;
- }
val = (val & AVS_TMON_STATUS_data_msk) >> AVS_TMON_STATUS_data_shift;
@@ -91,11 +91,8 @@ static int dove_get_temp(struct thermal_zone_device *thermal,
/* Valid check */
reg = readl_relaxed(priv->control + PMU_TEMP_DIOD_CTRL1_REG);
- if ((reg & PMU_TDC1_TEMP_VALID_MASK) == 0x0) {
- dev_err(&thermal->device,
- "Temperature sensor reading not valid\n");
+ if ((reg & PMU_TDC1_TEMP_VALID_MASK) == 0x0)
return -EIO;
- }
/*
* Calculate temperature. According to Marvell internal
@@ -436,9 +436,6 @@ static int hisi_thermal_get_temp(struct thermal_zone_device *tz, int *temp)
*temp = data->ops->get_temp(sensor);
- dev_dbg(&data->pdev->dev, "tzd=%p, id=%d, temp=%d, thres=%d\n",
- sensor->tzd, sensor->id, *temp, sensor->thres_temp);
-
return 0;
}
@@ -58,11 +58,8 @@ static int imx_sc_thermal_get_temp(struct thermal_zone_device *tz, int *temp)
hdr->size = 2;
ret = imx_scu_call_rpc(thermal_ipc_handle, &msg, true);
- if (ret) {
- dev_err(&sensor->tzd->device, "read temp sensor %d failed, ret %d\n",
- sensor->resource_id, ret);
+ if (ret)
return ret;
- }
*temp = msg.data.resp.celsius * 1000 + msg.data.resp.tenths * 100;
@@ -265,10 +265,8 @@ static int imx_get_temp(struct thermal_zone_device *tz, int *temp)
regmap_read(map, soc_data->temp_data, &val);
- if ((val & soc_data->temp_valid_mask) == 0) {
- dev_dbg(&tz->device, "temp measurement never finished\n");
+ if ((val & soc_data->temp_valid_mask) == 0)
return -EAGAIN;
- }
n_meas = (val & soc_data->temp_value_mask)
>> soc_data->temp_value_shift;
@@ -33,11 +33,8 @@ static int kirkwood_get_temp(struct thermal_zone_device *thermal,
/* Valid check */
if (!((reg >> KIRKWOOD_THERMAL_VALID_OFFSET) &
- KIRKWOOD_THERMAL_VALID_MASK)) {
- dev_err(&thermal->device,
- "Temperature sensor reading not valid\n");
+ KIRKWOOD_THERMAL_VALID_MASK))
return -EIO;
- }
/*
* Calculate temperature. According to Marvell internal
@@ -51,10 +51,8 @@ static int max77620_thermal_read_temp(struct thermal_zone_device *tz, int *temp)
int ret;
ret = regmap_read(mtherm->rmap, MAX77620_REG_STATLBT, &val);
- if (ret < 0) {
- dev_err(mtherm->dev, "Failed to read STATLBT: %d\n", ret);
+ if (ret < 0)
return ret;
- }
if (val & MAX77620_IRQ_TJALRM2_MASK)
*temp = MAX77620_TJALARM2_TEMP;
@@ -1233,9 +1233,6 @@ static int rockchip_thermal_get_temp(struct thermal_zone_device *tz, int *out_te
retval = tsadc->get_temp(&tsadc->table,
sensor->id, thermal->regs, out_temp);
- dev_dbg(&thermal->pdev->dev, "sensor %d - temp: %d, retval: %d\n",
- sensor->id, *out_temp, retval);
-
return retval;
}
@@ -127,8 +127,6 @@ static int st_thermal_get_temp(struct thermal_zone_device *th, int *temperature)
temp += sensor->cdata->temp_adjust_val;
temp = mcelsius(temp);
- dev_dbg(dev, "temperature: %d\n", temp);
-
*temperature = temp;
return 0;
@@ -59,10 +59,9 @@ static int gadc_thermal_get_temp(struct thermal_zone_device *tz, int *temp)
int ret;
ret = iio_read_channel_processed(gti->channel, &val);
- if (ret < 0) {
- dev_err(gti->dev, "IIO channel read failed %d\n", ret);
+ if (ret < 0)
return ret;
- }
+
*temp = gadc_thermal_adc_to_temp(gti, val);
return 0;