@@ -395,18 +395,24 @@ static int ip5xxx_battery_get_property(struct power_supply *psy,
case POWER_SUPPLY_PROP_VOLTAGE_NOW:
ret = ip5xxx_battery_read_adc(ip5xxx, &ip5xxx->regs.battery.adc.volt, &raw);
+ if (ret)
+ return ret;
val->intval = 2600000 + DIV_ROUND_CLOSEST(raw * 26855, 100);
return 0;
case POWER_SUPPLY_PROP_VOLTAGE_OCV:
ret = ip5xxx_battery_read_adc(ip5xxx, &ip5xxx->regs.battery.adc.open_volt, &raw);
+ if (ret)
+ return ret;
val->intval = 2600000 + DIV_ROUND_CLOSEST(raw * 26855, 100);
return 0;
case POWER_SUPPLY_PROP_CURRENT_NOW:
ret = ip5xxx_battery_read_adc(ip5xxx, &ip5xxx->regs.battery.adc.curr, &raw);
+ if (ret)
+ return ret;
val->intval = DIV_ROUND_CLOSEST(raw * 149197, 200);
return 0;
If ADC read returns an error, the return value was silently ignored, execution continued and an uninitialized value and a return code of 0 was passed back to userspace. The only exception was POWER_SUPPLY_PROP_CONSTANT_CHARGE_CURRENT, which bailed out correctly. Fix returns for the other cases as well. Fixes: 75853406fa27 ("power: supply: Add a driver for Injoinic power bank ICs") Signed-off-by: Csókás, Bence <csokas.bence@prolan.hu> --- drivers/power/supply/ip5xxx_power.c | 6 ++++++ 1 file changed, 6 insertions(+)