diff mbox

[1/3] dt-bindings: thermal/armada: describe AP806 and CP110

Message ID 7102bb32704ac9f70ef3ae61682d50de8af61b57.1511361725.git.baruch@tkos.co.il (mailing list archive)
State Superseded, archived
Delegated to: Eduardo Valentin
Headers show

Commit Message

Baruch Siach Nov. 22, 2017, 2:42 p.m. UTC
Add compatible strings for AP806 and CP110 that are part of the Armada 8k/7k
line of SoCs.

Add a note on the difference in the size of the control area in different
bindings. This is an existing difference between the Armada 375 binding and
the rest. The new AP806 and CP110 bindings are similar to the existing Armada
375 in this regard.

Signed-off-by: Baruch Siach <baruch@tkos.co.il>
---
 Documentation/devicetree/bindings/thermal/armada-thermal.txt | 10 +++++++++-
 1 file changed, 9 insertions(+), 1 deletion(-)
diff mbox

Patch

diff --git a/Documentation/devicetree/bindings/thermal/armada-thermal.txt b/Documentation/devicetree/bindings/thermal/armada-thermal.txt
index 24aacf8948c5..5ec944d4138b 100644
--- a/Documentation/devicetree/bindings/thermal/armada-thermal.txt
+++ b/Documentation/devicetree/bindings/thermal/armada-thermal.txt
@@ -7,12 +7,20 @@  Required properties:
 		marvell,armada375-thermal
 		marvell,armada380-thermal
 		marvell,armadaxp-thermal
+		marvell,armada-ap806-thermal
+		marvell,armada-cp110-thermal
 
 - reg:		Device's register space.
 		Two entries are expected, see the examples below.
 		The first one is required for the sensor register;
-		the second one is required for the control register
+		the second one is required for the control area
 		to be used for sensor initialization (a.k.a. calibration).
+		The size of the control area must be 4 for
+		marvell,armada370-thermal, marvell,armada380-thermal, and
+		marvell,armadaxp-thermal. The size must be 8 for
+		marvell,armada375-thermal, marvell,armada-ap806-thermal, and
+		marvell,armada-cp110-thermal.
+
 
 Example: