@@ -271,6 +271,19 @@ static bool is_full_charged(struct charger_manager *cm)
if (!fuel_gauge)
return false;
+ /* Full, if it's over the fullbatt voltage */
+ if (desc->fullbatt_uV > 0) {
+ ret = get_batt_uV(cm, &uV);
+ if (!ret) {
+ /* Battery is already full, checks voltage drop. */
+ if (cm->battery_status == POWER_SUPPLY_STATUS_FULL
+ && desc->fullbatt_vchkdrop_uV)
+ uV += desc->fullbatt_vchkdrop_uV;
+ if (uV >= desc->fullbatt_uV)
+ return true;
+ }
+ }
+
if (desc->fullbatt_full_capacity > 0) {
val.intval = 0;
@@ -283,15 +296,6 @@ static bool is_full_charged(struct charger_manager *cm)
}
}
- /* Full, if it's over the fullbatt voltage */
- if (desc->fullbatt_uV > 0) {
- ret = get_batt_uV(cm, &uV);
- if (!ret && uV >= desc->fullbatt_uV) {
- is_full = true;
- goto out;
- }
- }
-
/* Full, if the capacity is more than fullbatt_soc */
if (desc->fullbatt_soc > 0) {
val.intval = 0;
@@ -406,66 +410,12 @@ static int try_charger_enable(struct charger_manager *cm, bool enable)
}
}
- if (!err) {
+ if (!err)
cm->charger_enabled = enable;
- power_supply_changed(cm->charger_psy);
- }
return err;
}
-/**
- * try_charger_restart - Restart charging.
- * @cm: the Charger Manager representing the battery.
- *
- * Restart charging by turning off and on the charger.
- */
-static int try_charger_restart(struct charger_manager *cm)
-{
- int err;
-
- if (cm->emergency_stop)
- return -EAGAIN;
-
- err = try_charger_enable(cm, false);
- if (err)
- return err;
-
- return try_charger_enable(cm, true);
-}
-
-/**
- * fullbatt_vchk - Check voltage drop some times after "FULL" event.
- *
- * If a user has designated "fullbatt_vchkdrop_uV" values with
- * charger_desc, Charger Manager checks voltage drop after the battery
- * "FULL" event. It checks whether the voltage has dropped more than
- * fullbatt_vchkdrop_uV by calling this function after fullbatt_vchkrop_ms.
- */
-static void fullbatt_vchk(struct charger_manager *cm)
-{
- struct charger_desc *desc = cm->desc;
- int batt_uV, err, diff;
-
- if (!desc->fullbatt_vchkdrop_uV)
- return;
-
- err = get_batt_uV(cm, &batt_uV);
- if (err) {
- dev_err(cm->dev, "%s: get_batt_uV error(%d)\n", __func__, err);
- return;
- }
-
- diff = desc->fullbatt_uV - batt_uV;
- if (diff < 0)
- return;
-
- dev_info(cm->dev, "VBATT dropped %duV after full-batt\n", diff);
-
- if (diff > desc->fullbatt_vchkdrop_uV)
- try_charger_restart(cm);
-}
-
/**
* check_charging_duration - Monitor charging/discharging duration
* @cm: the Charger Manager representing the battery.
@@ -493,17 +443,14 @@ static int check_charging_duration(struct charger_manager *cm)
if (duration > desc->charging_max_duration_ms) {
dev_info(cm->dev, "Charging duration exceed %ums\n",
desc->charging_max_duration_ms);
- try_charger_enable(cm, false);
ret = true;
}
- } else if (is_ext_pwr_online(cm) && !cm->charger_enabled) {
+ } else if (cm->battery_status == POWER_SUPPLY_STATUS_NOT_CHARGING) {
duration = curr - cm->charging_end_time;
- if (duration > desc->discharging_max_duration_ms &&
- is_ext_pwr_online(cm)) {
+ if (duration > desc->charging_max_duration_ms) {
dev_info(cm->dev, "Discharging duration exceed %ums\n",
desc->discharging_max_duration_ms);
- try_charger_enable(cm, true);
ret = true;
}
}
@@ -585,9 +532,46 @@ static int cm_check_thermal_status(struct charger_manager *cm)
else
ret = CM_BATT_OK;
+ cm->emergency_stop = ret;
+
return ret;
}
+/**
+ * cm_get_target_status - Check current status and get next target status.
+ * @cm: the Charger Manager representing the battery.
+ */
+static int cm_get_target_status(struct charger_manager *cm)
+{
+ if (!is_ext_pwr_online(cm))
+ return POWER_SUPPLY_STATUS_DISCHARGING;
+
+ if (cm_check_thermal_status(cm)) {
+ /* Check if discharging duration exeeds limit. */
+ if (check_charging_duration(cm))
+ goto charging_ok;
+ return POWER_SUPPLY_STATUS_NOT_CHARGING;
+ }
+
+ switch (cm->battery_status) {
+ case POWER_SUPPLY_STATUS_CHARGING:
+ /* Check if charging duration exeeds limit. */
+ if (check_charging_duration(cm))
+ return POWER_SUPPLY_STATUS_FULL;
+ fallthrough;
+ case POWER_SUPPLY_STATUS_FULL:
+ if (is_full_charged(cm))
+ return POWER_SUPPLY_STATUS_FULL;
+ fallthrough;
+ default:
+ break;
+ }
+
+charging_ok:
+ /* Charging is allowed. */
+ return POWER_SUPPLY_STATUS_CHARGING;
+}
+
/**
* _cm_monitor - Monitor the temperature and return true for exceptions.
* @cm: the Charger Manager representing the battery.
@@ -597,56 +581,18 @@ static int cm_check_thermal_status(struct charger_manager *cm)
*/
static bool _cm_monitor(struct charger_manager *cm)
{
- int temp_alrt;
+ int target;
- temp_alrt = cm_check_thermal_status(cm);
+ target = cm_get_target_status(cm);
- /* It has been stopped already */
- if (temp_alrt && cm->emergency_stop)
- return false;
-
- /*
- * Check temperature whether overheat or cold.
- * If temperature is out of range normal state, stop charging.
- */
- if (temp_alrt) {
- cm->emergency_stop = temp_alrt;
- try_charger_enable(cm, false);
-
- /*
- * Check whole charging duration and discharging duration
- * after full-batt.
- */
- } else if (!cm->emergency_stop && check_charging_duration(cm)) {
- dev_dbg(cm->dev,
- "Charging/Discharging duration is out of range\n");
- /*
- * Check dropped voltage of battery. If battery voltage is more
- * dropped than fullbatt_vchkdrop_uV after fully charged state,
- * charger-manager have to recharge battery.
- */
- } else if (!cm->emergency_stop && is_ext_pwr_online(cm) &&
- !cm->charger_enabled) {
- fullbatt_vchk(cm);
+ try_charger_enable(cm, (target == POWER_SUPPLY_STATUS_CHARGING));
- /*
- * Check whether fully charged state to protect overcharge
- * if charger-manager is charging for battery.
- */
- } else if (!cm->emergency_stop && is_full_charged(cm) &&
- cm->charger_enabled) {
- dev_info(cm->dev, "EVENT_HANDLE: Battery Fully Charged\n");
- try_charger_enable(cm, false);
-
- fullbatt_vchk(cm);
- } else {
- cm->emergency_stop = 0;
- if (is_ext_pwr_online(cm)) {
- try_charger_enable(cm, true);
- }
+ if (cm->battery_status != target) {
+ cm->battery_status = target;
+ power_supply_changed(cm->charger_psy);
}
- return true;
+ return (cm->battery_status == POWER_SUPPLY_STATUS_NOT_CHARGING);
}
/**
@@ -751,12 +697,7 @@ static int charger_get_property(struct power_supply *psy,
switch (psp) {
case POWER_SUPPLY_PROP_STATUS:
- if (is_charging(cm))
- val->intval = POWER_SUPPLY_STATUS_CHARGING;
- else if (is_ext_pwr_online(cm))
- val->intval = POWER_SUPPLY_STATUS_NOT_CHARGING;
- else
- val->intval = POWER_SUPPLY_STATUS_DISCHARGING;
+ val->intval = cm->battery_status;
break;
case POWER_SUPPLY_PROP_HEALTH:
if (cm->emergency_stop > 0)
@@ -213,6 +213,7 @@ struct charger_desc {
* saved status of battery before entering suspend-to-RAM
* @charging_start_time: saved start time of enabling charging
* @charging_end_time: saved end time of disabling charging
+ * @battery_status: Current battery status
*/
struct charger_manager {
struct list_head entry;
@@ -232,6 +233,8 @@ struct charger_manager {
u64 charging_start_time;
u64 charging_end_time;
+
+ int battery_status;
};