Viresh Kumar Nov. 24, 2020, 6:26 a.m. UTC
Several parts of the kernel are already using the effective CPU
utilization (as seen by the scheduler) to get the current load on the
CPU, do the same here instead of depending on the idle time of the CPU,
which isn't that accurate comparatively.

This is also the right thing to do as it makes the cpufreq governor
(schedutil) align better with the cpufreq_cooling driver, as the power
requested by cpufreq_cooling governor will exactly match the next
frequency requested by the schedutil governor since they are both using
the same metric to calculate load.

This was tested on ARM Hikey6220 platform with hackbench, sysbench and
schbench. None of them showed any regression or significant
improvements. Schbench is the most important ones out of these as it
creates the scenario where the utilization numbers provide a better
estimate of the future.

Scenario 1: The CPUs were mostly idle in the previous polling window of
the IPA governor as the tasks were sleeping and here are the details
from traces (load is in %):

 Old: thermal_power_cpu_get_power: cpus=00000000,000000ff freq=1200000 total_load=203 load={{0x35,0x1,0x0,0x31,0x0,0x0,0x64,0x0}} dynamic_power=1339
 New: thermal_power_cpu_get_power: cpus=00000000,000000ff freq=1200000 total_load=600 load={{0x60,0x46,0x45,0x45,0x48,0x3b,0x61,0x44}} dynamic_power=3960

Here, the "Old" line gives the load and requested_power (dynamic_power
here) numbers calculated using the idle time based implementation, while
"New" is based on the CPU utilization from scheduler.

As can be clearly seen, the load and requested_power numbers are simply
incorrect in the idle time based approach and the numbers collected from
CPU's utilization are much closer to the reality.

Scenario 2: The CPUs were busy in the previous polling window of the IPA
governor:

 Old: thermal_power_cpu_get_power: cpus=00000000,000000ff freq=1200000 total_load=800 load={{0x64,0x64,0x64,0x64,0x64,0x64,0x64,0x64}} dynamic_power=5280
 New: thermal_power_cpu_get_power: cpus=00000000,000000ff freq=1200000 total_load=708 load={{0x4d,0x5c,0x5c,0x5b,0x5c,0x5c,0x51,0x5b}} dynamic_power=4672

As can be seen, the idle time based load is 100% for all the CPUs as it
took only the last window into account, but in reality the CPUs aren't
that loaded as shown by the utilization numbers.

Reviewed-by: Lukasz Luba <lukasz.luba@arm.com>
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
---
 drivers/thermal/cpufreq_cooling.c | 68 ++++++++++++++++++++++++-------
 1 file changed, 54 insertions(+), 14 deletions(-)

Comments

Dietmar Eggemann Dec. 3, 2020, 11:54 a.m. UTC | #1
On 24/11/2020 07:26, Viresh Kumar wrote:
> Several parts of the kernel are already using the effective CPU
> utilization (as seen by the scheduler) to get the current load on the
> CPU, do the same here instead of depending on the idle time of the CPU,
> which isn't that accurate comparatively.
> 
> This is also the right thing to do as it makes the cpufreq governor
> (schedutil) align better with the cpufreq_cooling driver, as the power
> requested by cpufreq_cooling governor will exactly match the next
> frequency requested by the schedutil governor since they are both using
> the same metric to calculate load.
> 
> This was tested on ARM Hikey6220 platform with hackbench, sysbench and
> schbench. None of them showed any regression or significant
> improvements. Schbench is the most important ones out of these as it
> creates the scenario where the utilization numbers provide a better
> estimate of the future.
> 
> Scenario 1: The CPUs were mostly idle in the previous polling window of
> the IPA governor as the tasks were sleeping and here are the details
> from traces (load is in %):
> 
>  Old: thermal_power_cpu_get_power: cpus=00000000,000000ff freq=1200000 total_load=203 load={{0x35,0x1,0x0,0x31,0x0,0x0,0x64,0x0}} dynamic_power=1339
>  New: thermal_power_cpu_get_power: cpus=00000000,000000ff freq=1200000 total_load=600 load={{0x60,0x46,0x45,0x45,0x48,0x3b,0x61,0x44}} dynamic_power=3960

When I ran schbench (-t 16 -r 5) on hikey960 I get multiple (~50)
instances of ~80ms task activity phase and then ~20ms idle phase on all
CPUs.

So I assume that scenario 1 is at the beginning (but you mentioned the
task were sleeping?) and scenario 2 is somewhere in the middle of the
testrun?
IMHO, the util-based approach delivers really better results at the
beginning and at the end of the entire testrun.
During the testrun, the util-based and the idle-based approach deliver
similar results.

It's a little bit tricky to compare test results since the IPA sampling
rate is 100ms and the load values you get depend on how the workload
pattern and the IPA sampling align.

> Here, the "Old" line gives the load and requested_power (dynamic_power
> here) numbers calculated using the idle time based implementation, while
> "New" is based on the CPU utilization from scheduler.
> 
> As can be clearly seen, the load and requested_power numbers are simply
> incorrect in the idle time based approach and the numbers collected from
> CPU's utilization are much closer to the reality.

I assume the IPA sampling is done after ~50ms of the first task activity
phase.

> Scenario 2: The CPUs were busy in the previous polling window of the IPA
> governor:
> 
>  Old: thermal_power_cpu_get_power: cpus=00000000,000000ff freq=1200000 total_load=800 load={{0x64,0x64,0x64,0x64,0x64,0x64,0x64,0x64}} dynamic_power=5280
>  New: thermal_power_cpu_get_power: cpus=00000000,000000ff freq=1200000 total_load=708 load={{0x4d,0x5c,0x5c,0x5b,0x5c,0x5c,0x51,0x5b}} dynamic_power=4672
> 
> As can be seen, the idle time based load is 100% for all the CPUs as it
> took only the last window into account, but in reality the CPUs aren't
> that loaded as shown by the utilization numbers.

Is this an IPA sampling at the end of the ~20ms idle phase?

[...]
Viresh Kumar Dec. 7, 2020, 12:17 p.m. UTC | #2
On 03-12-20, 12:54, Dietmar Eggemann wrote:
> On 24/11/2020 07:26, Viresh Kumar wrote:
> > Several parts of the kernel are already using the effective CPU
> > utilization (as seen by the scheduler) to get the current load on the
> > CPU, do the same here instead of depending on the idle time of the CPU,
> > which isn't that accurate comparatively.
> > 
> > This is also the right thing to do as it makes the cpufreq governor
> > (schedutil) align better with the cpufreq_cooling driver, as the power
> > requested by cpufreq_cooling governor will exactly match the next
> > frequency requested by the schedutil governor since they are both using
> > the same metric to calculate load.
> > 
> > This was tested on ARM Hikey6220 platform with hackbench, sysbench and
> > schbench. None of them showed any regression or significant
> > improvements. Schbench is the most important ones out of these as it
> > creates the scenario where the utilization numbers provide a better
> > estimate of the future.
> > 
> > Scenario 1: The CPUs were mostly idle in the previous polling window of
> > the IPA governor as the tasks were sleeping and here are the details
> > from traces (load is in %):
> > 
> >  Old: thermal_power_cpu_get_power: cpus=00000000,000000ff freq=1200000 total_load=203 load={{0x35,0x1,0x0,0x31,0x0,0x0,0x64,0x0}} dynamic_power=1339
> >  New: thermal_power_cpu_get_power: cpus=00000000,000000ff freq=1200000 total_load=600 load={{0x60,0x46,0x45,0x45,0x48,0x3b,0x61,0x44}} dynamic_power=3960
> 
> When I ran schbench (-t 16 -r 5) on hikey960 I get multiple (~50)
> instances of ~80ms task activity phase and then ~20ms idle phase on all
> CPUs.
> 
> So I assume that scenario 1 is at the beginning (but you mentioned the
> task were sleeping?)

I am not able to find the exact values I used, but I did something
like this to create a scenario where the old computations shall find
the CPU as idle in the last IPA window:

- schbench -m 2 -t 4 -s 25000 -c 20000 -r 60

- sampling rate of IPA to 10 ms

With this IPA wakes up many times and finds the CPUs to have been idle
in the last IPA window (i.e. 10ms).

> and scenario 2 is somewhere in the middle of the
> testrun?

This also happens all the time, as there will be cases when the IPA
runs and finds the CPUs to be always running in last 10 ms.

> IMHO, the util-based approach delivers really better results at the
> beginning and at the end of the entire testrun.
> During the testrun, the util-based and the idle-based approach deliver
> similar results.
> 
> It's a little bit tricky to compare test results since the IPA sampling
> rate is 100ms and the load values you get depend on how the workload
> pattern and the IPA sampling align.

Right.

> > Here, the "Old" line gives the load and requested_power (dynamic_power
> > here) numbers calculated using the idle time based implementation, while
> > "New" is based on the CPU utilization from scheduler.
> > 
> > As can be clearly seen, the load and requested_power numbers are simply
> > incorrect in the idle time based approach and the numbers collected from
> > CPU's utilization are much closer to the reality.
> 
> I assume the IPA sampling is done after ~50ms of the first task activity
> phase.
> 
> > Scenario 2: The CPUs were busy in the previous polling window of the IPA
> > governor:
> > 
> >  Old: thermal_power_cpu_get_power: cpus=00000000,000000ff freq=1200000 total_load=800 load={{0x64,0x64,0x64,0x64,0x64,0x64,0x64,0x64}} dynamic_power=5280
> >  New: thermal_power_cpu_get_power: cpus=00000000,000000ff freq=1200000 total_load=708 load={{0x4d,0x5c,0x5c,0x5b,0x5c,0x5c,0x51,0x5b}} dynamic_power=4672
> > 
> > As can be seen, the idle time based load is 100% for all the CPUs as it
> > took only the last window into account, but in reality the CPUs aren't
> > that loaded as shown by the utilization numbers.
> 
> Is this an IPA sampling at the end of the ~20ms idle phase?

This is during the phase where the CPUs were fully busy for the last
period.
Dietmar Eggemann Dec. 8, 2020, 12:31 p.m. UTC | #3
On 07/12/2020 13:17, Viresh Kumar wrote:
> On 03-12-20, 12:54, Dietmar Eggemann wrote:
>> On 24/11/2020 07:26, Viresh Kumar wrote:

[...]

>> When I ran schbench (-t 16 -r 5) on hikey960 I get multiple (~50)
>> instances of ~80ms task activity phase and then ~20ms idle phase on all
>> CPUs.
>>
>> So I assume that scenario 1 is at the beginning (but you mentioned the
>> task were sleeping?)
> 
> I am not able to find the exact values I used, but I did something
> like this to create a scenario where the old computations shall find
> the CPU as idle in the last IPA window:
> 
> - schbench -m 2 -t 4 -s 25000 -c 20000 -r 60
> 
> - sampling rate of IPA to 10 ms
> 
> With this IPA wakes up many times and finds the CPUs to have been idle
> in the last IPA window (i.e. 10ms).

Ah, this makes sense.

So with this there are only 8 worker threads w/ 20ms runtime and 75ms
period (30ms message thread time (-C) and 25 latency (-c)).

So much more idle time between two invocations of the worker/message
threads and more IPA sampling.

[...]

>>>  Old: thermal_power_cpu_get_power: cpus=00000000,000000ff freq=1200000 total_load=800 load={{0x64,0x64,0x64,0x64,0x64,0x64,0x64,0x64}} dynamic_power=5280
>>>  New: thermal_power_cpu_get_power: cpus=00000000,000000ff freq=1200000 total_load=708 load={{0x4d,0x5c,0x5c,0x5b,0x5c,0x5c,0x51,0x5b}} dynamic_power=4672
>>>
>>> As can be seen, the idle time based load is 100% for all the CPUs as it
>>> took only the last window into account, but in reality the CPUs aren't
>>> that loaded as shown by the utilization numbers.
>>
>> Is this an IPA sampling at the end of the ~20ms idle phase?
> 
> This is during the phase where the CPUs were fully busy for the last
> period.

OK.
diff mbox series

Patch

diff --git a/drivers/thermal/cpufreq_cooling.c b/drivers/thermal/cpufreq_cooling.c
index cc2959f22f01..5aff2ac4b77f 100644
--- a/drivers/thermal/cpufreq_cooling.c
+++ b/drivers/thermal/cpufreq_cooling.c
@@ -76,7 +76,9 @@  struct cpufreq_cooling_device {
 	struct em_perf_domain *em;
 	struct cpufreq_policy *policy;
 	struct list_head node;
+#ifndef CONFIG_SMP
 	struct time_in_idle *idle_time;
+#endif
 	struct freq_qos_request qos_req;
 };
 
@@ -132,14 +134,35 @@  static u32 cpu_power_to_freq(struct cpufreq_cooling_device *cpufreq_cdev,
 }
 
 /**
- * get_load() - get load for a cpu since last updated
- * @cpufreq_cdev:	&struct cpufreq_cooling_device for this cpu
- * @cpu:	cpu number
- * @cpu_idx:	index of the cpu in time_in_idle*
+ * get_load() - get load for a cpu
+ * @cpufreq_cdev: struct cpufreq_cooling_device for the cpu
+ * @cpu: cpu number
+ * @cpu_idx: index of the cpu in time_in_idle array
  *
  * Return: The average load of cpu @cpu in percentage since this
  * function was last called.
  */
+#ifdef CONFIG_SMP
+static u32 get_load(struct cpufreq_cooling_device *cpufreq_cdev, int cpu,
+		    int cpu_idx)
+{
+	unsigned long max = arch_scale_cpu_capacity(cpu);
+	unsigned long util;
+
+	util = sched_cpu_util(cpu, ENERGY_UTIL, max);
+	return (util * 100) / max;
+}
+
+static inline int allocate_idle_time(struct cpufreq_cooling_device *cpufreq_cdev)
+{
+	return 0;
+}
+
+static inline void free_idle_time(struct cpufreq_cooling_device *cpufreq_cdev)
+{
+}
+
+#else /* !CONFIG_SMP */
 static u32 get_load(struct cpufreq_cooling_device *cpufreq_cdev, int cpu,
 		    int cpu_idx)
 {
@@ -162,6 +185,26 @@  static u32 get_load(struct cpufreq_cooling_device *cpufreq_cdev, int cpu,
 	return load;
 }
 
+static int allocate_idle_time(struct cpufreq_cooling_device *cpufreq_cdev)
+{
+	unsigned int num_cpus = cpumask_weight(cpufreq_cdev->policy->related_cpus);
+
+	cpufreq_cdev->idle_time = kcalloc(num_cpus,
+					  sizeof(*cpufreq_cdev->idle_time),
+					  GFP_KERNEL);
+	if (!cpufreq_cdev->idle_time)
+		return -ENOMEM;
+
+	return 0;
+}
+
+static void free_idle_time(struct cpufreq_cooling_device *cpufreq_cdev)
+{
+	kfree(cpufreq_cdev->idle_time);
+	cpufreq_cdev->idle_time = NULL;
+}
+#endif /* CONFIG_SMP */
+
 /**
  * get_dynamic_power() - calculate the dynamic power
  * @cpufreq_cdev:	&cpufreq_cooling_device for this cdev
@@ -487,7 +530,7 @@  __cpufreq_cooling_register(struct device_node *np,
 	struct thermal_cooling_device *cdev;
 	struct cpufreq_cooling_device *cpufreq_cdev;
 	char dev_name[THERMAL_NAME_LENGTH];
-	unsigned int i, num_cpus;
+	unsigned int i;
 	struct device *dev;
 	int ret;
 	struct thermal_cooling_device_ops *cooling_ops;
@@ -498,7 +541,6 @@  __cpufreq_cooling_register(struct device_node *np,
 		return ERR_PTR(-ENODEV);
 	}
 
-
 	if (IS_ERR_OR_NULL(policy)) {
 		pr_err("%s: cpufreq policy isn't valid: %p\n", __func__, policy);
 		return ERR_PTR(-EINVAL);
@@ -516,12 +558,10 @@  __cpufreq_cooling_register(struct device_node *np,
 		return ERR_PTR(-ENOMEM);
 
 	cpufreq_cdev->policy = policy;
-	num_cpus = cpumask_weight(policy->related_cpus);
-	cpufreq_cdev->idle_time = kcalloc(num_cpus,
-					 sizeof(*cpufreq_cdev->idle_time),
-					 GFP_KERNEL);
-	if (!cpufreq_cdev->idle_time) {
-		cdev = ERR_PTR(-ENOMEM);
+
+	ret = allocate_idle_time(cpufreq_cdev);
+	if (ret) {
+		cdev = ERR_PTR(ret);
 		goto free_cdev;
 	}
 
@@ -581,7 +621,7 @@  __cpufreq_cooling_register(struct device_node *np,
 remove_ida:
 	ida_simple_remove(&cpufreq_ida, cpufreq_cdev->id);
 free_idle_time:
-	kfree(cpufreq_cdev->idle_time);
+	free_idle_time(cpufreq_cdev);
 free_cdev:
 	kfree(cpufreq_cdev);
 	return cdev;
@@ -674,7 +714,7 @@  void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev)
 	thermal_cooling_device_unregister(cdev);
 	freq_qos_remove_request(&cpufreq_cdev->qos_req);
 	ida_simple_remove(&cpufreq_ida, cpufreq_cdev->id);
-	kfree(cpufreq_cdev->idle_time);
+	free_idle_time(cpufreq_cdev);
 	kfree(cpufreq_cdev);
 }
 EXPORT_SYMBOL_GPL(cpufreq_cooling_unregister);