diff mbox

[v2,1/4] dt-bindings: thermal/armada: describe AP806 and CP110

Message ID f8c589337a4fb78852eadf15058e8f8d132d4dc0.1512299484.git.baruch@tkos.co.il (mailing list archive)
State Superseded, archived
Delegated to: Eduardo Valentin
Headers show

Commit Message

Baruch Siach Dec. 3, 2017, 11:11 a.m. UTC
Add compatible strings for AP806 and CP110 that are part of the Armada 8k/7k
line of SoCs.

Add a note on the difference in the size of the control area in different
bindings. This is an existing difference between the Armada 375 binding and
the rest. The new AP806 and CP110 bindings are similar to the existing Armada
375 in this regard.

Signed-off-by: Baruch Siach <baruch@tkos.co.il>
---
v2: No change
---
 Documentation/devicetree/bindings/thermal/armada-thermal.txt | 9 ++++++++-
 1 file changed, 8 insertions(+), 1 deletion(-)

Comments

Rob Herring (Arm) Dec. 4, 2017, 10:33 p.m. UTC | #1
On Sun, Dec 03, 2017 at 01:11:21PM +0200, Baruch Siach wrote:
> Add compatible strings for AP806 and CP110 that are part of the Armada 8k/7k
> line of SoCs.
> 
> Add a note on the difference in the size of the control area in different
> bindings. This is an existing difference between the Armada 375 binding and
> the rest. The new AP806 and CP110 bindings are similar to the existing Armada
> 375 in this regard.
> 
> Signed-off-by: Baruch Siach <baruch@tkos.co.il>
> ---
> v2: No change
> ---
>  Documentation/devicetree/bindings/thermal/armada-thermal.txt | 9 ++++++++-
>  1 file changed, 8 insertions(+), 1 deletion(-)

Reviewed-by: Rob Herring <robh@kernel.org>
diff mbox

Patch

diff --git a/Documentation/devicetree/bindings/thermal/armada-thermal.txt b/Documentation/devicetree/bindings/thermal/armada-thermal.txt
index 24aacf8948c5..eec57f509166 100644
--- a/Documentation/devicetree/bindings/thermal/armada-thermal.txt
+++ b/Documentation/devicetree/bindings/thermal/armada-thermal.txt
@@ -7,12 +7,19 @@  Required properties:
 		marvell,armada375-thermal
 		marvell,armada380-thermal
 		marvell,armadaxp-thermal
+		marvell,armada-ap806-thermal
+		marvell,armada-cp110-thermal
 
 - reg:		Device's register space.
 		Two entries are expected, see the examples below.
 		The first one is required for the sensor register;
-		the second one is required for the control register
+		the second one is required for the control area
 		to be used for sensor initialization (a.k.a. calibration).
+		The size of the control area must be 4 for
+		marvell,armada370-thermal, marvell,armada380-thermal, and
+		marvell,armadaxp-thermal. The size must be 8 for
+		marvell,armada375-thermal, marvell,armada-ap806-thermal, and
+		marvell,armada-cp110-thermal.
 
 Example: