diff mbox series

[v3,1/2] thermal: rcar_thermal: Remove temperature bound

Message ID 20200117160554.3812787-2-niklas.soderlund+renesas@ragnatech.se (mailing list archive)
State Mainlined
Commit dff6d4f80509d1aaf07da9534f3f4b6876876caf
Delegated to: Geert Uytterhoeven
Headers show
Series thermal: rcar_{gen3_}thermal: Remove temperature | expand

Commit Message

Niklas Söderlund Jan. 17, 2020, 4:05 p.m. UTC
The hardware manual states that the operation of the sensor is not
guaranteed outside the range of -45°C to 125°C, not that the readings
are invalid. Remove the bound check and try to deliver temperature
readings even if we are outside the guaranteed operation range.

Signed-off-by: Niklas Söderlund <niklas.soderlund+renesas@ragnatech.se>
---
* Changes since v2
- s/ragne/range/

* Changes since v1
- Preserver the guaranteed operating range in a comment.
---
 drivers/thermal/rcar_thermal.c | 7 +------
 1 file changed, 1 insertion(+), 6 deletions(-)
diff mbox series

Patch

diff --git a/drivers/thermal/rcar_thermal.c b/drivers/thermal/rcar_thermal.c
index d0873de718da9218..49d351f77bf6e6fc 100644
--- a/drivers/thermal/rcar_thermal.c
+++ b/drivers/thermal/rcar_thermal.c
@@ -275,12 +275,7 @@  static int rcar_thermal_get_current_temp(struct rcar_thermal_priv *priv,
 		tmp = MCELSIUS((priv->ctemp * 5) - 60);
 	mutex_unlock(&priv->lock);
 
-	if ((tmp < MCELSIUS(-45)) || (tmp > MCELSIUS(125))) {
-		struct device *dev = rcar_priv_to_dev(priv);
-
-		dev_err(dev, "it couldn't measure temperature correctly\n");
-		return -EIO;
-	}
+	/* Guaranteed operating range is -45C to 125C. */
 
 	*temp = tmp;