@@ -170,11 +170,12 @@ static struct clk * __init rza2_cpg_clk_register(struct device *dev,
if (IS_ERR(parent))
return ERR_CAST(parent);
- switch (core->id) {
- case CLK_MAIN:
+ switch (core->type) {
+ case CLK_TYPE_RZA_MAIN:
+ r7s9210_update_clk_table(parent, base);
break;
- case CLK_PLL:
+ case CLK_TYPE_RZA_PLL:
if (cpg_mode)
mult = 44; /* Divider 1 is 1/2 */
else
@@ -185,9 +186,6 @@ static struct clk * __init rza2_cpg_clk_register(struct device *dev,
return ERR_PTR(-EINVAL);
}
- if (core->id == CLK_MAIN)
- r7s9210_update_clk_table(parent, base);
-
return clk_register_fixed_factor(NULL, core->name,
__clk_get_name(parent), 0, mult, div);
}
When registering a clock, its type should be devised from the clock's type member, not from its id member. Merge the two checks for the main clock, to improve readability. Signed-off-by: Geert Uytterhoeven <geert+renesas@glider.be> --- drivers/clk/renesas/r7s9210-cpg-mssr.c | 10 ++++------ 1 file changed, 4 insertions(+), 6 deletions(-)