Message ID | 20201023181629.119727-1-maccraft123mc@gmail.com (mailing list archive) |
---|---|
State | New, archived |
Headers | show |
Series | Fix poweroff issue on Odroid Go Advance | expand |
On Fri, 23 Oct 2020 20:16:29 +0200, Maciej Matuszczyk wrote:
>
Applied, thanks!
[1/1] arm64: dts: rockchip: Remove system-power-controller from pmic on Odroid Go Advance
commit: 01fe332800d0d2f94337b45c1973f4cf28ae6195
Best regards,
diff --git a/arch/arm64/boot/dts/rockchip/rk3326-odroid-go2.dts b/arch/arm64/boot/dts/rockchip/rk3326-odroid-go2.dts index 35bd6b904b9c..337681038519 100644 --- a/arch/arm64/boot/dts/rockchip/rk3326-odroid-go2.dts +++ b/arch/arm64/boot/dts/rockchip/rk3326-odroid-go2.dts @@ -243,7 +243,6 @@ rk817: pmic@20 { interrupts = <RK_PB2 IRQ_TYPE_LEVEL_LOW>; pinctrl-names = "default"; pinctrl-0 = <&pmic_int>; - rockchip,system-power-controller; wakeup-source; #clock-cells = <1>; clock-output-names = "rk808-clkout1", "xin32k";