@@ -9,10 +9,23 @@ Optional properties :
(datasheet-recommended value is 10000).
Defining this property enables current-sense functionality.
+Optional threshold properties :
+ If skipped the condition won't be reported.
+ - maxim,cold-temp : Temperature threshold to report battery
+ as cold (in tenths of degree Celsius).
+ - maxim,over-heat-temp : Temperature threshold to report battery
+ as over heated (in tenths of degree Celsius).
+ - maxim,dead-volt : Voltage threshold to report battery
+ as dead (in mV).
+ - maxim,over-volt : Voltage threshold to report battery
+ as over voltage (in mV).
+
Example:
battery-charger@36 {
compatible = "maxim,max17042";
reg = <0x36>;
maxim,rsns-microohm = <10000>;
+ maxim,over-heat-temp = <600>;
+ maxim,over-volt = <4300>;
};
@@ -818,6 +818,15 @@ max17042_get_pdata(struct device *dev)
pdata->enable_current_sense = true;
}
+ if (of_property_read_s32(np, "maxim,cold-temp", &pdata->temp_min))
+ pdata->temp_min = INT_MIN;
+ if (of_property_read_s32(np, "maxim,over-heat-temp", &pdata->temp_max))
+ pdata->temp_max = INT_MAX;
+ if (of_property_read_s32(np, "maxim,dead-volt", &pdata->vmin))
+ pdata->vmin = INT_MIN;
+ if (of_property_read_s32(np, "maxim,over-volt", &pdata->vmax))
+ pdata->vmax = INT_MAX;
+
return pdata;
}
#else
The commit edd4ab055931 ("power: max17042_battery: add HEALTH and TEMP_* properties support") added support for setting voltage and temperature thresholds with platform data. For DeviceTree default of 0 was always used. This caused reporting battery health always as over voltage or over heated. Signed-off-by: Krzysztof Kozlowski <k.kozlowski@samsung.com> Fixes: edd4ab055931 ("power: max17042_battery: add HEALTH and TEMP_* properties support") --- .../devicetree/bindings/power_supply/max17042_battery.txt | 13 +++++++++++++ drivers/power/max17042_battery.c | 9 +++++++++ 2 files changed, 22 insertions(+)