[10/18] smartpqi: update volume size after expansion

Message ID 164375211833.440833.17023155389220583731.stgit@brunhilda.pdev.net (mailing list archive)
State Accepted
Headers show
Series smartpqi updates | expand

Commit Message

Don Brace Feb. 1, 2022, 9:48 p.m. UTC
From: Mahesh Rajashekhara <mahesh.rajashekhara@microchip.com>

Rescan devices after volume expansion.

After modifying logical volume size, lsblk command still shows up
previous size of logical volume.

When driver gets any event from f/w, driver schedules rescan worker
with delay of 10 seconds.

If array expansion is so quick and gets complete in a second,
driver could not catch logical volume expansion due to worker delay.

Since driver does not detect volume expansion, driver would not call
rescan device to update new size to the OS.

Reviewed-by: Kevin Barnett <kevin.barnett@microchip.com>
Reviewed-by: Mike McGowen <mike.mcgowen@microchip.com>
Reviewed-by: Scott Benesh <scott.benesh@microchip.com>
Reviewed-by: Scott Teel <scott.teel@microchip.com>
Signed-off-by: Mahesh Rajashekhara <mahesh.rajashekhara@microchip.com>
Signed-off-by: Don Brace <don.brace@microchip.com>
---
 drivers/scsi/smartpqi/smartpqi.h      |    1 +
 drivers/scsi/smartpqi/smartpqi_init.c |   20 ++++++++++++--------
 2 files changed, 13 insertions(+), 8 deletions(-)
diff mbox series

Patch

diff --git a/drivers/scsi/smartpqi/smartpqi.h b/drivers/scsi/smartpqi/smartpqi.h
index 81ec5fbf570a..4f6e48854c66 100644
--- a/drivers/scsi/smartpqi/smartpqi.h
+++ b/drivers/scsi/smartpqi/smartpqi.h
@@ -1322,6 +1322,7 @@  struct pqi_ctrl_info {
 	bool		controller_online;
 	bool		block_requests;
 	bool		scan_blocked;
+	u8		logical_volume_rescan_needed : 1;
 	u8		inbound_spanning_supported : 1;
 	u8		outbound_spanning_supported : 1;
 	u8		pqi_mode_enabled : 1;
diff --git a/drivers/scsi/smartpqi/smartpqi_init.c b/drivers/scsi/smartpqi/smartpqi_init.c
index ab12507da436..de53180fab9c 100644
--- a/drivers/scsi/smartpqi/smartpqi_init.c
+++ b/drivers/scsi/smartpqi/smartpqi_init.c
@@ -2015,8 +2015,8 @@  static void pqi_dev_info(struct pqi_ctrl_info *ctrl_info,
 
 /* Assumes the SCSI device list lock is held. */
 
-static void pqi_scsi_update_device(struct pqi_scsi_dev *existing_device,
-	struct pqi_scsi_dev *new_device)
+static void pqi_scsi_update_device(struct pqi_ctrl_info *ctrl_info,
+	struct pqi_scsi_dev *existing_device, struct pqi_scsi_dev *new_device)
 {
 	existing_device->device_type = new_device->device_type;
 	existing_device->bus = new_device->bus;
@@ -2026,9 +2026,8 @@  static void pqi_scsi_update_device(struct pqi_scsi_dev *existing_device,
 		existing_device->target_lun_valid = true;
 	}
 
-	if ((existing_device->volume_status == CISS_LV_QUEUED_FOR_EXPANSION ||
-		existing_device->volume_status == CISS_LV_UNDERGOING_EXPANSION) &&
-		new_device->volume_status == CISS_LV_OK)
+	if (pqi_is_logical_device(existing_device) &&
+		ctrl_info->logical_volume_rescan_needed)
 		existing_device->rescan = true;
 
 	/* By definition, the scsi3addr and wwid fields are already the same. */
@@ -2146,7 +2145,7 @@  static void pqi_update_device_list(struct pqi_ctrl_info *ctrl_info,
 			 */
 			device->new_device = false;
 			matching_device->device_gone = false;
-			pqi_scsi_update_device(matching_device, device);
+			pqi_scsi_update_device(ctrl_info, matching_device, device);
 			break;
 		case DEVICE_NOT_FOUND:
 			/*
@@ -2218,8 +2217,8 @@  static void pqi_update_device_list(struct pqi_ctrl_info *ctrl_info,
 	}
 
 	/*
-	 * Notify the SCSI ML if the queue depth of any existing device has
-	 * changed.
+	 * Notify the SML of any existing device changes such as;
+	 * queue depth, device size.
 	 */
 	list_for_each_entry(device, &ctrl_info->scsi_device_list, scsi_device_list_entry) {
 		if (device->sdev && device->queue_depth != device->advertised_queue_depth) {
@@ -2248,6 +2247,9 @@  static void pqi_update_device_list(struct pqi_ctrl_info *ctrl_info,
 			}
 		}
 	}
+
+	ctrl_info->logical_volume_rescan_needed = false;
+
 }
 
 static inline bool pqi_is_supported_device(struct pqi_scsi_dev *device)
@@ -3703,6 +3705,8 @@  static void pqi_event_worker(struct work_struct *work)
 			} else {
 				ack_event = true;
 				rescan_needed = true;
+				if (event->event_type == PQI_EVENT_TYPE_LOGICAL_DEVICE)
+					ctrl_info->logical_volume_rescan_needed = true;
 			}
 			if (ack_event)
 				pqi_acknowledge_event(ctrl_info, event);