@@ -29,6 +29,7 @@
#include <linux/pinctrl/machine.h>
#include <linux/platform_data/gpio-rcar.h>
#include <linux/platform_device.h>
+#include <linux/phy.h>
#include <linux/regulator/fixed.h>
#include <linux/regulator/machine.h>
#include <linux/sh_eth.h>
@@ -155,6 +156,30 @@ static void __init lager_add_standard_devices(void)
ðer_pdata, sizeof(ether_pdata));
}
+/*
+ * Ether LEDs on the Lager board are named LINK and ACTIVE which corresponds
+ * to non-default 01 setting of the Micrel KSZ8041 PHY control register 1 bits
+ * 14-15. We have to set them back to 01 from the default 00 value each time
+ * the PHY is reset. It's also important because the PHY's LED0 signal is
+ * connected to SoC's ETH_LINK signal and in the PHY's default mode it will
+ * bounce on and off after each packet, which we apparently want to avoid.
+ */
+static int lager_ksz8041_fixup(struct phy_device *phydev)
+{
+ u16 phyctrl1 = phy_read(phydev, 0x1e);
+
+ phyctrl1 &= ~0xc000;
+ phyctrl1 |= 0x4000;
+ return phy_write(phydev, 0x1e, phyctrl1);
+}
+
+static void __init lager_init(void)
+{
+ lager_add_standard_devices();
+
+ phy_register_fixup_for_id("r8a7790-ether-ff:01", lager_ksz8041_fixup);
+}
+
static const char *lager_boards_compat_dt[] __initdata = {
"renesas,lager",
NULL,
@@ -163,6 +188,6 @@ static const char *lager_boards_compat_dt[] __initdata = {
DT_MACHINE_START(LAGER_DT, "lager")
.init_early = r8a7790_init_delay,
.init_time = r8a7790_timer_init,
- .init_machine = lager_add_standard_devices,
+ .init_machine = lager_init,
.dt_compat = lager_boards_compat_dt,
MACHINE_END