diff mbox series

[v2,7/7] ARM: imx7d: remove Atheros AR8031 PHY fixup

Message ID 20210309112615.625-8-o.rempel@pengutronix.de (mailing list archive)
State Deferred
Delegated to: Netdev Maintainers
Headers show
Series remove different PHY fixups | expand

Checks

Context Check Description
netdev/tree_selection success Not a local patch

Commit Message

Oleksij Rempel March 9, 2021, 11:26 a.m. UTC
This fixup configures the IO voltage and disables the SmartEEE
functionality.

If this patch breaks your system, enable AT803X_PHY driver and configure
the PHY by the device tree:

	phy-connection-type = "rgmii-id";
	ethernet-phy@X {
		reg = <0xX>;

		qca,smarteee-tw-us-1g = <24>;

		vddio-supply = <&vddh>;

		vddio: vddio-regulator {
			regulator-name = "VDDIO";
			regulator-min-microvolt = <1800000>;
			regulator-max-microvolt = <1800000>;
		};

		vddh: vddh-regulator {
			regulator-name = "VDDH";
		};
	};

Signed-off-by: Oleksij Rempel <o.rempel@pengutronix.de>
---
 arch/arm/mach-imx/mach-imx7d.c | 22 ----------------------
 1 file changed, 22 deletions(-)
diff mbox series

Patch

diff --git a/arch/arm/mach-imx/mach-imx7d.c b/arch/arm/mach-imx/mach-imx7d.c
index 879c35929a13..ccf64ddf8b7e 100644
--- a/arch/arm/mach-imx/mach-imx7d.c
+++ b/arch/arm/mach-imx/mach-imx7d.c
@@ -14,25 +14,6 @@ 
 
 #include "common.h"
 
-static int ar8031_phy_fixup(struct phy_device *dev)
-{
-	u16 val;
-
-	/* Set RGMII IO voltage to 1.8V */
-	phy_write(dev, 0x1d, 0x1f);
-	phy_write(dev, 0x1e, 0x8);
-
-	/* disable phy AR8031 SmartEEE function. */
-	phy_write(dev, 0xd, 0x3);
-	phy_write(dev, 0xe, 0x805d);
-	phy_write(dev, 0xd, 0x4003);
-	val = phy_read(dev, 0xe);
-	val &= ~(0x1 << 8);
-	phy_write(dev, 0xe, val);
-
-	return 0;
-}
-
 static int bcm54220_phy_fixup(struct phy_device *dev)
 {
 	/* enable RXC skew select RGMII copper mode */
@@ -44,14 +25,11 @@  static int bcm54220_phy_fixup(struct phy_device *dev)
 	return 0;
 }
 
-#define PHY_ID_AR8031	0x004dd074
 #define PHY_ID_BCM54220	0x600d8589
 
 static void __init imx7d_enet_phy_init(void)
 {
 	if (IS_BUILTIN(CONFIG_PHYLIB)) {
-		phy_register_fixup_for_uid(PHY_ID_AR8031, 0xffffffff,
-					   ar8031_phy_fixup);
 		phy_register_fixup_for_uid(PHY_ID_BCM54220, 0xffffffff,
 					   bcm54220_phy_fixup);
 	}