Message ID | 20230817120111.3522827-1-vladimir.oltean@nxp.com (mailing list archive) |
---|---|
State | Accepted |
Commit | d44036cad31170da0cb9c728e80743f84267da6e |
Delegated to: | Netdev Maintainers |
Headers | show |
Series | [net] net: dsa: felix: fix oversize frame dropping for always closed tc-taprio gates | expand |
On Thu, Aug 17, 2023 at 03:01:11PM +0300, Vladimir Oltean wrote: > The blamed commit resolved a bug where frames would still get stuck at > egress, even though they're smaller than the maxSDU[tc], because the > driver did not take into account the extra 33 ns that the queue system > needs for scheduling the frame. > > It now takes that into account, but the arithmetic that we perform in > vsc9959_tas_remaining_gate_len_ps() is buggy, because we operate on > 64-bit unsigned integers, so gate_len_ns - VSC9959_TAS_MIN_GATE_LEN_NS > may become a very large integer if gate_len_ns < 33 ns. > > In practice, this means that we've introduced a regression where all > traffic class gates which are permanently closed will not get detected > by the driver, and we won't enable oversize frame dropping for them. > > Before: > mscc_felix 0000:00:00.5: port 0: max frame size 1526 needs 12400000 ps, 1152000 ps for mPackets at speed 1000 > mscc_felix 0000:00:00.5: port 0 tc 0 min gate len 1000000, sending all frames > mscc_felix 0000:00:00.5: port 0 tc 1 min gate len 0, sending all frames > mscc_felix 0000:00:00.5: port 0 tc 2 min gate len 0, sending all frames > mscc_felix 0000:00:00.5: port 0 tc 3 min gate len 0, sending all frames > mscc_felix 0000:00:00.5: port 0 tc 4 min gate len 0, sending all frames > mscc_felix 0000:00:00.5: port 0 tc 5 min gate len 0, sending all frames > mscc_felix 0000:00:00.5: port 0 tc 6 min gate len 0, sending all frames > mscc_felix 0000:00:00.5: port 0 tc 7 min gate length 5120 ns not enough for max frame size 1526 at 1000 Mbps, dropping frames over 615 octets including FCS > > After: > mscc_felix 0000:00:00.5: port 0: max frame size 1526 needs 12400000 ps, 1152000 ps for mPackets at speed 1000 > mscc_felix 0000:00:00.5: port 0 tc 0 min gate len 1000000, sending all frames > mscc_felix 0000:00:00.5: port 0 tc 1 min gate length 0 ns not enough for max frame size 1526 at 1000 Mbps, dropping frames over 1 octets including FCS > mscc_felix 0000:00:00.5: port 0 tc 2 min gate length 0 ns not enough for max frame size 1526 at 1000 Mbps, dropping frames over 1 octets including FCS > mscc_felix 0000:00:00.5: port 0 tc 3 min gate length 0 ns not enough for max frame size 1526 at 1000 Mbps, dropping frames over 1 octets including FCS > mscc_felix 0000:00:00.5: port 0 tc 4 min gate length 0 ns not enough for max frame size 1526 at 1000 Mbps, dropping frames over 1 octets including FCS > mscc_felix 0000:00:00.5: port 0 tc 5 min gate length 0 ns not enough for max frame size 1526 at 1000 Mbps, dropping frames over 1 octets including FCS > mscc_felix 0000:00:00.5: port 0 tc 6 min gate length 0 ns not enough for max frame size 1526 at 1000 Mbps, dropping frames over 1 octets including FCS > mscc_felix 0000:00:00.5: port 0 tc 7 min gate length 5120 ns not enough for max frame size 1526 at 1000 Mbps, dropping frames over 615 octets including FCS > > Fixes: 11afdc6526de ("net: dsa: felix: tc-taprio intervals smaller than MTU should send at least one packet") > Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com> Reviewed-by: Simon Horman <horms@kernel.org>
Hello: This patch was applied to netdev/net.git (main) by Jakub Kicinski <kuba@kernel.org>: On Thu, 17 Aug 2023 15:01:11 +0300 you wrote: > The blamed commit resolved a bug where frames would still get stuck at > egress, even though they're smaller than the maxSDU[tc], because the > driver did not take into account the extra 33 ns that the queue system > needs for scheduling the frame. > > It now takes that into account, but the arithmetic that we perform in > vsc9959_tas_remaining_gate_len_ps() is buggy, because we operate on > 64-bit unsigned integers, so gate_len_ns - VSC9959_TAS_MIN_GATE_LEN_NS > may become a very large integer if gate_len_ns < 33 ns. > > [...] Here is the summary with links: - [net] net: dsa: felix: fix oversize frame dropping for always closed tc-taprio gates https://git.kernel.org/netdev/net/c/d44036cad311 You are awesome, thank you!
diff --git a/drivers/net/dsa/ocelot/felix_vsc9959.c b/drivers/net/dsa/ocelot/felix_vsc9959.c index 4a6e52929d25..3c5509e75a54 100644 --- a/drivers/net/dsa/ocelot/felix_vsc9959.c +++ b/drivers/net/dsa/ocelot/felix_vsc9959.c @@ -1070,6 +1070,9 @@ static u64 vsc9959_tas_remaining_gate_len_ps(u64 gate_len_ns) if (gate_len_ns == U64_MAX) return U64_MAX; + if (gate_len_ns < VSC9959_TAS_MIN_GATE_LEN_NS) + return 0; + return (gate_len_ns - VSC9959_TAS_MIN_GATE_LEN_NS) * PSEC_PER_NSEC; }
The blamed commit resolved a bug where frames would still get stuck at egress, even though they're smaller than the maxSDU[tc], because the driver did not take into account the extra 33 ns that the queue system needs for scheduling the frame. It now takes that into account, but the arithmetic that we perform in vsc9959_tas_remaining_gate_len_ps() is buggy, because we operate on 64-bit unsigned integers, so gate_len_ns - VSC9959_TAS_MIN_GATE_LEN_NS may become a very large integer if gate_len_ns < 33 ns. In practice, this means that we've introduced a regression where all traffic class gates which are permanently closed will not get detected by the driver, and we won't enable oversize frame dropping for them. Before: mscc_felix 0000:00:00.5: port 0: max frame size 1526 needs 12400000 ps, 1152000 ps for mPackets at speed 1000 mscc_felix 0000:00:00.5: port 0 tc 0 min gate len 1000000, sending all frames mscc_felix 0000:00:00.5: port 0 tc 1 min gate len 0, sending all frames mscc_felix 0000:00:00.5: port 0 tc 2 min gate len 0, sending all frames mscc_felix 0000:00:00.5: port 0 tc 3 min gate len 0, sending all frames mscc_felix 0000:00:00.5: port 0 tc 4 min gate len 0, sending all frames mscc_felix 0000:00:00.5: port 0 tc 5 min gate len 0, sending all frames mscc_felix 0000:00:00.5: port 0 tc 6 min gate len 0, sending all frames mscc_felix 0000:00:00.5: port 0 tc 7 min gate length 5120 ns not enough for max frame size 1526 at 1000 Mbps, dropping frames over 615 octets including FCS After: mscc_felix 0000:00:00.5: port 0: max frame size 1526 needs 12400000 ps, 1152000 ps for mPackets at speed 1000 mscc_felix 0000:00:00.5: port 0 tc 0 min gate len 1000000, sending all frames mscc_felix 0000:00:00.5: port 0 tc 1 min gate length 0 ns not enough for max frame size 1526 at 1000 Mbps, dropping frames over 1 octets including FCS mscc_felix 0000:00:00.5: port 0 tc 2 min gate length 0 ns not enough for max frame size 1526 at 1000 Mbps, dropping frames over 1 octets including FCS mscc_felix 0000:00:00.5: port 0 tc 3 min gate length 0 ns not enough for max frame size 1526 at 1000 Mbps, dropping frames over 1 octets including FCS mscc_felix 0000:00:00.5: port 0 tc 4 min gate length 0 ns not enough for max frame size 1526 at 1000 Mbps, dropping frames over 1 octets including FCS mscc_felix 0000:00:00.5: port 0 tc 5 min gate length 0 ns not enough for max frame size 1526 at 1000 Mbps, dropping frames over 1 octets including FCS mscc_felix 0000:00:00.5: port 0 tc 6 min gate length 0 ns not enough for max frame size 1526 at 1000 Mbps, dropping frames over 1 octets including FCS mscc_felix 0000:00:00.5: port 0 tc 7 min gate length 5120 ns not enough for max frame size 1526 at 1000 Mbps, dropping frames over 615 octets including FCS Fixes: 11afdc6526de ("net: dsa: felix: tc-taprio intervals smaller than MTU should send at least one packet") Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com> --- drivers/net/dsa/ocelot/felix_vsc9959.c | 3 +++ 1 file changed, 3 insertions(+)