diff mbox series

[net-next,8/8] Documentation: networking: document phy_link_topology

Message ID 20240409105847.465298-9-maxime.chevallier@bootlin.com (mailing list archive)
State Changes Requested
Delegated to: Netdev Maintainers
Headers show
Series net: Allow targeting specific PHYs through netlink | expand

Checks

Context Check Description
netdev/series_format success Posting correctly formatted
netdev/tree_selection success Clearly marked for net-next
netdev/ynl success Generated files up to date; no warnings/errors; GEN HAS DIFF 2 files changed, 911 insertions(+);
netdev/fixes_present success Fixes tag not required for -next series
netdev/header_inline success No static functions without inline keyword in header files
netdev/build_32bit success Errors and warnings before: 948 this patch: 948
netdev/build_tools success No tools touched, skip
netdev/cc_maintainers warning 1 maintainers not CCed: linux-doc@vger.kernel.org
netdev/build_clang success Errors and warnings before: 954 this patch: 954
netdev/verify_signedoff success Signed-off-by tag matches author and committer
netdev/deprecated_api success None detected
netdev/check_selftest success No net selftest shell script
netdev/verify_fixes success No Fixes tag
netdev/build_allmodconfig_warn success Errors and warnings before: 960 this patch: 960
netdev/checkpatch warning WARNING: added, moved or deleted file(s), does MAINTAINERS need updating?
netdev/build_clang_rust success No Rust files in patch. Skipping build
netdev/kdoc success Errors and warnings before: 0 this patch: 0
netdev/source_inline success Was 0 now: 0
netdev/contest fail net-next-2024-04-09--18-00 (tests: 958)

Commit Message

Maxime Chevallier April 9, 2024, 10:58 a.m. UTC
The newly introduced phy_link_topology tracks all ethernet PHYs that are
attached to a netdevice. Document the base principle, internal and
external APIs. As the phy_link_topology is expected to be extended, this
documentation will hold any further improvements and additions made
relative to topology handling.

Signed-off-by: Maxime Chevallier <maxime.chevallier@bootlin.com>
Reviewed-by: Andrew Lunn <andrew@lunn.ch>
---
 Documentation/networking/ethtool-netlink.rst  |   3 +
 Documentation/networking/index.rst            |   1 +
 .../networking/phy-link-topology.rst          | 120 ++++++++++++++++++
 3 files changed, 124 insertions(+)
 create mode 100644 Documentation/networking/phy-link-topology.rst

Comments

Jakub Kicinski April 9, 2024, 6:45 p.m. UTC | #1
On Tue,  9 Apr 2024 12:58:46 +0200 Maxime Chevallier wrote:
> +For more information, refer to :ref:`Documentation/networking/phy-link-topology.rst`

make htmldocs seems upset by this:

WARNING: undefined label: 'documentation/networking/phy-link-topology.rst'

I always struggle with the cross-file links TBH :S
diff mbox series

Patch

diff --git a/Documentation/networking/ethtool-netlink.rst b/Documentation/networking/ethtool-netlink.rst
index b89a3d562018..1ae3bfd805ce 100644
--- a/Documentation/networking/ethtool-netlink.rst
+++ b/Documentation/networking/ethtool-netlink.rst
@@ -2027,10 +2027,13 @@  Retrieve information about a given Ethernet PHY sitting on the link. The DO
 operation returns all available information about dev->phydev. User can also
 specify a PHY_INDEX, in which case the DO request returns information about that
 specific PHY.
+
 As there can be more than one PHY, the DUMP operation can be used to list the PHYs
 present on a given interface, by passing an interface index or name in
 the dump request.
 
+For more information, refer to :ref:`Documentation/networking/phy-link-topology.rst`
+
 Request contents:
 
   ====================================  ======  ==========================
diff --git a/Documentation/networking/index.rst b/Documentation/networking/index.rst
index 473d72c36d61..c29bc5179d8a 100644
--- a/Documentation/networking/index.rst
+++ b/Documentation/networking/index.rst
@@ -89,6 +89,7 @@  Contents:
    operstates
    packet_mmap
    phonet
+   phy-link-topology
    pktgen
    plip
    ppp_generic
diff --git a/Documentation/networking/phy-link-topology.rst b/Documentation/networking/phy-link-topology.rst
new file mode 100644
index 000000000000..1f021419ae8c
--- /dev/null
+++ b/Documentation/networking/phy-link-topology.rst
@@ -0,0 +1,120 @@ 
+.. SPDX-License-Identifier: GPL-2.0
+
+=================
+PHY link topology
+=================
+
+Overview
+========
+
+The PHY link topology representation in the networking stack aims at representing
+the hardware layout for any given Ethernet link.
+
+An Ethernet interface from userspace's point of view is nothing but a
+:c:type:`struct net_device <net_device>`, which exposes configuration options
+through the legacy ioctls and the ethtool netlink commands. The base assumption
+when designing these configuration APIs were that the link looks something like ::
+
+  +-----------------------+        +----------+      +--------------+
+  | Ethernet Controller / |        | Ethernet |      | Connector /  |
+  |       MAC             | ------ |   PHY    | ---- |    Port      | ---... to LP
+  +-----------------------+        +----------+      +--------------+
+  struct net_device               struct phy_device
+
+Commands that needs to configure the PHY will go through the net_device.phydev
+field to reach the PHY and perform the relevant configuration.
+
+This assumption falls apart in more complex topologies that can arise when,
+for example, using SFP transceivers (although that's not the only specific case).
+
+Here, we have 2 basic scenarios. Either the MAC is able to output a serialized
+interface, that can directly be fed to an SFP cage, such as SGMII, 1000BaseX,
+10GBaseR, etc.
+
+The link topology then looks like this (when an SFP module is inserted) ::
+
+  +-----+  SGMII  +------------+
+  | MAC | ------- | SFP Module |
+  +-----+         +------------+
+
+Knowing that some modules embed a PHY, the actual link is more like ::
+
+  +-----+  SGMII   +--------------+
+  | MAC | -------- | PHY (on SFP) |
+  +-----+          +--------------+
+
+In this case, the SFP PHY is handled by phylib, and registered by phylink through
+its SFP upstream ops.
+
+Now some Ethernet controllers aren't able to output a serialized interface, so
+we can't directly connect them to an SFP cage. However, some PHYs can be used
+as media-converters, to translate the non-serialized MAC MII interface to a
+serialized MII interface fed to the SFP ::
+
+  +-----+  RGMII  +-----------------------+  SGMII  +--------------+
+  | MAC | ------- | PHY (media converter) | ------- | PHY (on SFP) |
+  +-----+         +-----------------------+         +--------------+
+
+This is where the model of having a single net_device.phydev pointer shows its
+limitations, as we now have 2 PHYs on the link.
+
+The phy_link topology framework aims at providing a way to keep track of every
+PHY on the link, for use by both kernel drivers and subsystems, but also to
+report the topology to userspace, allowing to target individual PHYs in configuration
+commands.
+
+API
+===
+
+The :c:type:`struct phy_link_topology <phy_link_topology>` is a per-netdevice
+resource, that gets initialized at netdevice creation. Once it's initialized,
+it is then possible to register PHYs to the topology through :
+
+:c:func:`phy_link_topo_add_phy`
+
+Besides registering the PHY to the topology, this call will also assign a unique
+index to the PHY, which can then be reported to userspace to refer to this PHY
+(akin to the ifindex). This index is a u32, ranging from 1 to U32_MAX. The value
+0 is reserved to indicate the PHY doesn't belong to any topology yet.
+
+The PHY can then be removed from the topology through
+
+:c:func:`phy_link_topo_del_phy`
+
+These function are already hooked into the phylib subsystem, so all PHYs that
+are linked to a net_device through :c:func:`phy_attach_direct` will automatically
+join the netdev's topology.
+
+PHYs that are on a SFP module will also be automatically registered IF the SFP
+upstream is phylink (so, no media-converter).
+
+PHY drivers that can be used as SFP upstream need to call :c:func:`phy_sfp_attach_phy`
+and :c:func:`phy_sfp_detach_phy`, which can be used as a
+.attach_phy / .detach_phy implementation for the
+:c:type:`struct sfp_upstream_ops <sfp_upstream_ops>`.
+
+UAPI
+====
+
+There exist a set of netlink commands to query the link topology from userspace,
+see ``Documentation/networking/ethtool-netlink.rst``.
+
+The whole point of having a topology representation is to assign the phyindex
+field in :c:type:`struct phy_device <phy_device>`. This index is reported to
+userspace using the ``ETHTOOL_MSG_PHY_GET`` ethtnl command. Performing a DUMP operation
+will result in all PHYs from all net_device being listed. The DUMP command
+accepts either a ``ETHTOOL_A_HEADER_DEV_INDEX`` or ``ETHTOOL_A_HEADER_DEV_NAME``
+to be passed in the request to filter the DUMP to a single net_device.
+
+The retrieved index can then be passed as a request parameter using the
+``ETHTOOL_A_HEADER_PHY_INDEX`` field in the following ethnl commands :
+
+* ``ETHTOOL_MSG_STRSET_GET`` to get the stats string set from a given PHY
+* ``ETHTOOL_MSG_CABLE_TEST_ACT`` and ``ETHTOOL_MSG_CABLE_TEST_ACT``, to perform
+  cable testing on a given PHY on the link (most likely the outermost PHY)
+* ``ETHTOOL_MSG_PSE_SET`` and ``ETHTOOL_MSG_PSE_GET`` for PHY-controlled PoE and PSE settings
+* ``ETHTOOL_MSG_PLCA_GET_CFG``, ``ETHTOOL_MSG_PLCA_SET_CFG`` and ``ETHTOOL_MSG_PLCA_GET_STATUS``
+  to set the PLCA (Physical Layer Collision Avoidance) parameters
+
+Note that the PHY index can be passed to other requests, which will silently
+ignore it if present and irrelevant.