mbox series

[v3,0/6] Support discontinuous PMU counters

Message ID 20231013110111.34619-1-rbradford@rivosinc.com (mailing list archive)
Headers show
Series Support discontinuous PMU counters | expand

Message

Rob Bradford Oct. 13, 2023, 10:54 a.m. UTC
Currently the available PMU counters start at HPM3 and run through to
the number specified by the "pmu-num" property. There is no
requirement in the specification that the available counters be
continously numbered. This series add suppport for specifying a
discountinuous range of counters though a "pmu-mask" property.

v3:

* Use env_archcpu() in csr.c
* Re-added check to enforce deprectated "num-pmu" below limit
* Check that standard counters are not included in mask
* Remove use of MAKE_32BIT_MASK()

v2:

* Use cfg.pmu_mask wherever cfg.pmu_num was used previously
* Deprecate pmu_num property (warning, comment & updated documentation)
* Override default pmu_mask value iff pmu_num changed from default

Rob Bradford (6):
  target/riscv: Propagate error from PMU setup
  target/riscv: Don't assume PMU counters are continuous
  target/riscv: Use existing PMU counter mask in FDT generation
  target/riscv: Add "pmu-mask" property to replace "pmu-num"
  docs/about/deprecated: Document RISC-V "pmu-num" deprecation
  target/riscv: Use MAKE_64BIT_MASK instead of custom macro

 docs/about/deprecated.rst | 10 ++++++++++
 hw/riscv/virt.c           |  2 +-
 target/riscv/cpu.c        | 13 ++++++++++---
 target/riscv/cpu_cfg.h    |  3 ++-
 target/riscv/csr.c        |  5 +++--
 target/riscv/machine.c    |  2 +-
 target/riscv/pmu.c        | 41 ++++++++++++++++++++++-----------------
 target/riscv/pmu.h        |  5 +++--
 8 files changed, 53 insertions(+), 28 deletions(-)