diff mbox

[PULL,1/3] vhost: check for vhost_ops before using.

Message ID 1470842980-32481-2-git-send-email-mst@redhat.com (mailing list archive)
State New, archived
Headers show

Commit Message

Michael S. Tsirkin Aug. 10, 2016, 3:30 p.m. UTC
From: Ilya Maximets <i.maximets@samsung.com>

'vhost_set_vring_enable()' tries to call function using pointer to
'vhost_ops' which can be already zeroized in 'vhost_dev_cleanup()'
while vhost disconnection.

Fix that by checking 'vhost_ops' before using. This fixes QEMU crash
on calling 'ethtool -L eth0 combined 2' if vhost disconnected.

Signed-off-by: Ilya Maximets <i.maximets@samsung.com>
Reviewed-by: Michael S. Tsirkin <mst@redhat.com>
Signed-off-by: Michael S. Tsirkin <mst@redhat.com>
---
 hw/net/vhost_net.c | 2 +-
 1 file changed, 1 insertion(+), 1 deletion(-)
diff mbox

Patch

diff --git a/hw/net/vhost_net.c b/hw/net/vhost_net.c
index dc61dc1..f2d49ad 100644
--- a/hw/net/vhost_net.c
+++ b/hw/net/vhost_net.c
@@ -428,7 +428,7 @@  int vhost_set_vring_enable(NetClientState *nc, int enable)
 
     nc->vring_enable = enable;
 
-    if (vhost_ops->vhost_set_vring_enable) {
+    if (vhost_ops && vhost_ops->vhost_set_vring_enable) {
         return vhost_ops->vhost_set_vring_enable(&net->dev, enable);
     }