diff mbox series

[v11,02/13] hw/block/nvme: Generate namespace UUIDs

Message ID 20201208200410.27900-3-dmitry.fomichev@wdc.com (mailing list archive)
State New, archived
Headers show
Series hw/block/nvme: Support Namespace Types and Zoned Namespace Command Set | expand

Commit Message

Dmitry Fomichev Dec. 8, 2020, 8:03 p.m. UTC
In NVMe 1.4, a namespace must report an ID descriptor of UUID type
if it doesn't support EUI64 or NGUID. Add a new namespace property,
"uuid", that provides the user the option to either specify the UUID
explicitly or have a UUID generated automatically every time a
namespace is initialized.

Suggested-by: Klaus Jensen <k.jensen@samsung.com>
Signed-off-by: Dmitry Fomichev <dmitry.fomichev@wdc.com>
Reviewed-by: Klaus Jensen <k.jensen@samsung.com>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Reviewed-by: Niklas Cassel <Niklas.Cassel@wdc.com>
---
 hw/block/nvme-ns.h | 1 +
 hw/block/nvme-ns.c | 1 +
 hw/block/nvme.c    | 9 +++++----
 3 files changed, 7 insertions(+), 4 deletions(-)
diff mbox series

Patch

diff --git a/hw/block/nvme-ns.h b/hw/block/nvme-ns.h
index ed3d7e65d5..aeca810fc7 100644
--- a/hw/block/nvme-ns.h
+++ b/hw/block/nvme-ns.h
@@ -21,6 +21,7 @@ 
 
 typedef struct NvmeNamespaceParams {
     uint32_t nsid;
+    QemuUUID uuid;
 } NvmeNamespaceParams;
 
 typedef struct NvmeNamespace {
diff --git a/hw/block/nvme-ns.c b/hw/block/nvme-ns.c
index 9b95e2ed33..6349aa30be 100644
--- a/hw/block/nvme-ns.c
+++ b/hw/block/nvme-ns.c
@@ -152,6 +152,7 @@  static void nvme_ns_realize(DeviceState *dev, Error **errp)
 static Property nvme_ns_props[] = {
     DEFINE_BLOCK_PROPERTIES(NvmeNamespace, blkconf),
     DEFINE_PROP_UINT32("nsid", NvmeNamespace, params.nsid, 0),
+    DEFINE_PROP_UUID("uuid", NvmeNamespace, params.uuid),
     DEFINE_PROP_END_OF_LIST(),
 };
 
diff --git a/hw/block/nvme.c b/hw/block/nvme.c
index 10acb7e7f0..a30fe75620 100644
--- a/hw/block/nvme.c
+++ b/hw/block/nvme.c
@@ -1662,6 +1662,7 @@  static uint16_t nvme_identify_nslist(NvmeCtrl *n, NvmeRequest *req)
 
 static uint16_t nvme_identify_ns_descr_list(NvmeCtrl *n, NvmeRequest *req)
 {
+    NvmeNamespace *ns;
     NvmeIdentify *c = (NvmeIdentify *)&req->cmd;
     uint32_t nsid = le32_to_cpu(c->nsid);
     uint8_t list[NVME_IDENTIFY_DATA_SIZE];
@@ -1681,7 +1682,8 @@  static uint16_t nvme_identify_ns_descr_list(NvmeCtrl *n, NvmeRequest *req)
         return NVME_INVALID_NSID | NVME_DNR;
     }
 
-    if (unlikely(!nvme_ns(n, nsid))) {
+    ns = nvme_ns(n, nsid);
+    if (unlikely(!ns)) {
         return NVME_INVALID_FIELD | NVME_DNR;
     }
 
@@ -1690,12 +1692,11 @@  static uint16_t nvme_identify_ns_descr_list(NvmeCtrl *n, NvmeRequest *req)
     /*
      * Because the NGUID and EUI64 fields are 0 in the Identify Namespace data
      * structure, a Namespace UUID (nidt = 0x3) must be reported in the
-     * Namespace Identification Descriptor. Add a very basic Namespace UUID
-     * here.
+     * Namespace Identification Descriptor. Add the namespace UUID here.
      */
     ns_descrs->uuid.hdr.nidt = NVME_NIDT_UUID;
     ns_descrs->uuid.hdr.nidl = NVME_NIDT_UUID_LEN;
-    stl_be_p(&ns_descrs->uuid.v, nsid);
+    memcpy(&ns_descrs->uuid.v, ns->params.uuid.data, NVME_NIDT_UUID_LEN);
 
     return nvme_dma(n, list, NVME_IDENTIFY_DATA_SIZE,
                     DMA_DIRECTION_FROM_DEVICE, req);