On 25/4/24 01:31, Richard Henderson wrote: > The ilen value extracted from ex_value is the length of the > EXECUTE instruction itself, and so is the increment to the pc. > However, the length of the synthetic insn is located in the > opcode like all other instructions. > > Signed-off-by: Richard Henderson <richard.henderson@linaro.org> > --- > target/s390x/tcg/translate.c | 4 ++-- > 1 file changed, 2 insertions(+), 2 deletions(-) Reviewed-by: Philippe Mathieu-Daudé <philmd@linaro.org>
diff --git a/target/s390x/tcg/translate.c b/target/s390x/tcg/translate.c index 2eb787e401..95d4d6ebc3 100644 --- a/target/s390x/tcg/translate.c +++ b/target/s390x/tcg/translate.c @@ -6200,11 +6200,11 @@ static const DisasInsn *extract_insn(CPUS390XState *env, DisasContext *s) /* Extract the values saved by EXECUTE. */ insn = s->ex_value & 0xffffffffffff0000ull; ilen = s->ex_value & 0xf; + op = insn >> 56; /* Register insn bytes with translator so plugins work. */ be_insn = cpu_to_be64(insn); - translator_fake_ld(&s->base, &be_insn, ilen); - op = insn >> 56; + translator_fake_ld(&s->base, &be_insn, get_ilen(op)); } else { insn = ld_code2(env, s, pc); op = (insn >> 8) & 0xff;
The ilen value extracted from ex_value is the length of the EXECUTE instruction itself, and so is the increment to the pc. However, the length of the synthetic insn is located in the opcode like all other instructions. Signed-off-by: Richard Henderson <richard.henderson@linaro.org> --- target/s390x/tcg/translate.c | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-)