diff mbox series

[3/7] tests/qtest: don't step clock at start of npcm7xx periodic IRQ test

Message ID 20250120210212.3890255-4-alex.bennee@linaro.org (mailing list archive)
State New
Headers show
Series testing/next (qtest timer stuff) | expand

Commit Message

Alex Bennée Jan. 20, 2025, 9:02 p.m. UTC
Until there are timers enabled the semantics of clock_step_next() will
fail. Since d524441a36 (system/qtest: properly feedback results of
clock_[step|set]) we will signal a FAIL if time doesn't advance.

Signed-off-by: Alex Bennée <alex.bennee@linaro.org>
---
 tests/qtest/npcm7xx_timer-test.c | 1 -
 1 file changed, 1 deletion(-)
diff mbox series

Patch

diff --git a/tests/qtest/npcm7xx_timer-test.c b/tests/qtest/npcm7xx_timer-test.c
index 58f58c2f71..43711049ca 100644
--- a/tests/qtest/npcm7xx_timer-test.c
+++ b/tests/qtest/npcm7xx_timer-test.c
@@ -465,7 +465,6 @@  static void test_periodic_interrupt(gconstpointer test_data)
     int i;
 
     tim_reset(td);
-    clock_step_next();
 
     tim_write_ticr(td, count);
     tim_write_tcsr(td, CEN | IE | MODE_PERIODIC | PRESCALE(ps));