On Sat, 31 Oct 2020 18:48:16 +0000 Jonathan Cameron <jic23@kernel.org> wrote: > From: Jonathan Cameron <Jonathan.Cameron@huawei.com> > > This basically has same questions as for the afe4403. We could combine > the two bindings, but as the drivers are separate and it would be a little > fiddly due to different buses let's keep the separating. > To repeat questions from the ti,afe4403 binding. > > A few questions came up whilst converting this one. > 1) What is actually required? > - Checking Linux driver, interrupt is not, and the tx-supply could > be supplied by a stub regulator as long as it's always on. > As such I have reduced the required list to just compatible and reg. > 2) What is the regulator called? > - It's tx-supply in the binding doc, but the driver request tx_sup > I've left this alone for now. Andrew could you confirm what is > intended for this? > > Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com> > Cc: Andrew F. Davis <afd@ti.com> Applied. with the maintainer switched to me for now as Andrew's email is bouncing. Thanks, Jonathan > --- > .../bindings/iio/health/afe4404.txt | 29 ----------- > .../bindings/iio/health/ti,afe4404.yaml | 51 +++++++++++++++++++ > 2 files changed, 51 insertions(+), 29 deletions(-) > > diff --git a/Documentation/devicetree/bindings/iio/health/afe4404.txt b/Documentation/devicetree/bindings/iio/health/afe4404.txt > deleted file mode 100644 > index 0b52830a0d9c..000000000000 > --- a/Documentation/devicetree/bindings/iio/health/afe4404.txt > +++ /dev/null > @@ -1,29 +0,0 @@ > -Texas Instruments AFE4404 Heart rate and Pulse Oximeter > - > -Required properties: > - - compatible : Should be "ti,afe4404". > - - reg : I2C address of the device. > - - tx-supply : Regulator supply to transmitting LEDs. > - - interrupts : The interrupt line the device ADC_RDY pin is > - connected to. For details refer to, > - ../interrupt-controller/interrupts.txt. > - > -Optional properties: > - - reset-gpios : GPIO used to reset the device. > - For details refer to, ../gpio/gpio.txt. > - > -Example: > - > -&i2c2 { > - heart_mon@58 { > - compatible = "ti,afe4404"; > - reg = <0x58>; > - > - tx-supply = <&vbat>; > - > - interrupt-parent = <&gpio1>; > - interrupts = <28 IRQ_TYPE_EDGE_RISING>; > - > - reset-gpios = <&gpio1 16 GPIO_ACTIVE_LOW>; > - }; > -}; > diff --git a/Documentation/devicetree/bindings/iio/health/ti,afe4404.yaml b/Documentation/devicetree/bindings/iio/health/ti,afe4404.yaml > new file mode 100644 > index 000000000000..187b99b22312 > --- /dev/null > +++ b/Documentation/devicetree/bindings/iio/health/ti,afe4404.yaml > @@ -0,0 +1,51 @@ > +# SPDX-License-Identifier: (GPL-2.0 OR BSD-2-Clause) > +%YAML 1.2 > +--- > +$id: http://devicetree.org/schemas/iio/health/ti,afe4404.yaml# > +$schema: http://devicetree.org/meta-schemas/core.yaml# > + > +title: Texas Instruments AFE4404 Heart rate and Pulse Oximeter > + > +maintainers: > + - Andrew F. Davis <afd@ti.com> > + > +properties: > + compatible: > + const: ti,afe4403 > + > + reg: > + maxItems: 1 > + > + tx-supply: > + description: Supply to transmitting LEDs. > + > + interrupts: > + maxItems: 1 > + description: Connected to ADC_RDY pin. > + > + reset-gpios: true > + > +additionalProperties: false > + > +required: > + - compatible > + - reg > + > +examples: > + - | > + #include <dt-bindings/gpio/gpio.h> > + #include <dt-bindings/interrupt-controller/irq.h> > + i2c { > + #address-cells = <1>; > + #size-cells = <0>; > + > + heart_mon@58 { > + compatible = "ti,afe4404"; > + reg = <0x58>; > + tx-supply = <&vbat>; > + interrupt-parent = <&gpio1>; > + interrupts = <28 IRQ_TYPE_EDGE_RISING>; > + reset-gpios = <&gpio1 16 GPIO_ACTIVE_LOW>; > + }; > + }; > +...
On Sat, Oct 31, 2020 at 1:51 PM Jonathan Cameron <jic23@kernel.org> wrote: > > From: Jonathan Cameron <Jonathan.Cameron@huawei.com> > > This basically has same questions as for the afe4403. We could combine > the two bindings, but as the drivers are separate and it would be a little > fiddly due to different buses let's keep the separating. > To repeat questions from the ti,afe4403 binding. > > A few questions came up whilst converting this one. > 1) What is actually required? > - Checking Linux driver, interrupt is not, and the tx-supply could > be supplied by a stub regulator as long as it's always on. > As such I have reduced the required list to just compatible and reg. > 2) What is the regulator called? > - It's tx-supply in the binding doc, but the driver request tx_sup > I've left this alone for now. Andrew could you confirm what is > intended for this? > > Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com> > Cc: Andrew F. Davis <afd@ti.com> > --- > .../bindings/iio/health/afe4404.txt | 29 ----------- > .../bindings/iio/health/ti,afe4404.yaml | 51 +++++++++++++++++++ > 2 files changed, 51 insertions(+), 29 deletions(-) > > diff --git a/Documentation/devicetree/bindings/iio/health/afe4404.txt b/Documentation/devicetree/bindings/iio/health/afe4404.txt > deleted file mode 100644 > index 0b52830a0d9c..000000000000 > --- a/Documentation/devicetree/bindings/iio/health/afe4404.txt > +++ /dev/null > @@ -1,29 +0,0 @@ > -Texas Instruments AFE4404 Heart rate and Pulse Oximeter > - > -Required properties: > - - compatible : Should be "ti,afe4404". > - - reg : I2C address of the device. > - - tx-supply : Regulator supply to transmitting LEDs. > - - interrupts : The interrupt line the device ADC_RDY pin is > - connected to. For details refer to, > - ../interrupt-controller/interrupts.txt. > - > -Optional properties: > - - reset-gpios : GPIO used to reset the device. > - For details refer to, ../gpio/gpio.txt. > - > -Example: > - > -&i2c2 { > - heart_mon@58 { > - compatible = "ti,afe4404"; > - reg = <0x58>; > - > - tx-supply = <&vbat>; > - > - interrupt-parent = <&gpio1>; > - interrupts = <28 IRQ_TYPE_EDGE_RISING>; > - > - reset-gpios = <&gpio1 16 GPIO_ACTIVE_LOW>; > - }; > -}; > diff --git a/Documentation/devicetree/bindings/iio/health/ti,afe4404.yaml b/Documentation/devicetree/bindings/iio/health/ti,afe4404.yaml > new file mode 100644 > index 000000000000..187b99b22312 > --- /dev/null > +++ b/Documentation/devicetree/bindings/iio/health/ti,afe4404.yaml > @@ -0,0 +1,51 @@ > +# SPDX-License-Identifier: (GPL-2.0 OR BSD-2-Clause) > +%YAML 1.2 > +--- > +$id: http://devicetree.org/schemas/iio/health/ti,afe4404.yaml# > +$schema: http://devicetree.org/meta-schemas/core.yaml# > + > +title: Texas Instruments AFE4404 Heart rate and Pulse Oximeter > + > +maintainers: > + - Andrew F. Davis <afd@ti.com> > + > +properties: > + compatible: > + const: ti,afe4403 Typo here, which causes this warning: Documentation/devicetree/bindings/iio/health/ti,afe4403.example.dt.yaml: heart_mon@0: 'spi-max-frequency' does not match any of the regexes: 'pinctrl-[0-9]+' Took me a minute staring at ti,afe4403.yaml to figure out what was happening. Rob
On Fri, 18 Dec 2020 13:42:19 -0600 Rob Herring <robh+dt@kernel.org> wrote: > On Sat, Oct 31, 2020 at 1:51 PM Jonathan Cameron <jic23@kernel.org> wrote: > > > > From: Jonathan Cameron <Jonathan.Cameron@huawei.com> > > > > This basically has same questions as for the afe4403. We could combine > > the two bindings, but as the drivers are separate and it would be a little > > fiddly due to different buses let's keep the separating. > > To repeat questions from the ti,afe4403 binding. > > > > A few questions came up whilst converting this one. > > 1) What is actually required? > > - Checking Linux driver, interrupt is not, and the tx-supply could > > be supplied by a stub regulator as long as it's always on. > > As such I have reduced the required list to just compatible and reg. > > 2) What is the regulator called? > > - It's tx-supply in the binding doc, but the driver request tx_sup > > I've left this alone for now. Andrew could you confirm what is > > intended for this? > > > > Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com> > > Cc: Andrew F. Davis <afd@ti.com> > > --- > > .../bindings/iio/health/afe4404.txt | 29 ----------- > > .../bindings/iio/health/ti,afe4404.yaml | 51 +++++++++++++++++++ > > 2 files changed, 51 insertions(+), 29 deletions(-) > > > > diff --git a/Documentation/devicetree/bindings/iio/health/afe4404.txt b/Documentation/devicetree/bindings/iio/health/afe4404.txt > > deleted file mode 100644 > > index 0b52830a0d9c..000000000000 > > --- a/Documentation/devicetree/bindings/iio/health/afe4404.txt > > +++ /dev/null > > @@ -1,29 +0,0 @@ > > -Texas Instruments AFE4404 Heart rate and Pulse Oximeter > > - > > -Required properties: > > - - compatible : Should be "ti,afe4404". > > - - reg : I2C address of the device. > > - - tx-supply : Regulator supply to transmitting LEDs. > > - - interrupts : The interrupt line the device ADC_RDY pin is > > - connected to. For details refer to, > > - ../interrupt-controller/interrupts.txt. > > - > > -Optional properties: > > - - reset-gpios : GPIO used to reset the device. > > - For details refer to, ../gpio/gpio.txt. > > - > > -Example: > > - > > -&i2c2 { > > - heart_mon@58 { > > - compatible = "ti,afe4404"; > > - reg = <0x58>; > > - > > - tx-supply = <&vbat>; > > - > > - interrupt-parent = <&gpio1>; > > - interrupts = <28 IRQ_TYPE_EDGE_RISING>; > > - > > - reset-gpios = <&gpio1 16 GPIO_ACTIVE_LOW>; > > - }; > > -}; > > diff --git a/Documentation/devicetree/bindings/iio/health/ti,afe4404.yaml b/Documentation/devicetree/bindings/iio/health/ti,afe4404.yaml > > new file mode 100644 > > index 000000000000..187b99b22312 > > --- /dev/null > > +++ b/Documentation/devicetree/bindings/iio/health/ti,afe4404.yaml > > @@ -0,0 +1,51 @@ > > +# SPDX-License-Identifier: (GPL-2.0 OR BSD-2-Clause) > > +%YAML 1.2 > > +--- > > +$id: http://devicetree.org/schemas/iio/health/ti,afe4404.yaml# > > +$schema: http://devicetree.org/meta-schemas/core.yaml# > > + > > +title: Texas Instruments AFE4404 Heart rate and Pulse Oximeter > > + > > +maintainers: > > + - Andrew F. Davis <afd@ti.com> > > + > > +properties: > > + compatible: > > + const: ti,afe4403 > > Typo here, which causes this warning: > > Documentation/devicetree/bindings/iio/health/ti,afe4403.example.dt.yaml: > heart_mon@0: 'spi-max-frequency' does not match any of the regexes: > 'pinctrl-[0-9]+' > > Took me a minute staring at ti,afe4403.yaml to figure out what was happening. Doh! Patch on it's way. Thanks, Jonathan > > Rob
diff --git a/Documentation/devicetree/bindings/iio/health/afe4404.txt b/Documentation/devicetree/bindings/iio/health/afe4404.txt deleted file mode 100644 index 0b52830a0d9c..000000000000 --- a/Documentation/devicetree/bindings/iio/health/afe4404.txt +++ /dev/null @@ -1,29 +0,0 @@ -Texas Instruments AFE4404 Heart rate and Pulse Oximeter - -Required properties: - - compatible : Should be "ti,afe4404". - - reg : I2C address of the device. - - tx-supply : Regulator supply to transmitting LEDs. - - interrupts : The interrupt line the device ADC_RDY pin is - connected to. For details refer to, - ../interrupt-controller/interrupts.txt. - -Optional properties: - - reset-gpios : GPIO used to reset the device. - For details refer to, ../gpio/gpio.txt. - -Example: - -&i2c2 { - heart_mon@58 { - compatible = "ti,afe4404"; - reg = <0x58>; - - tx-supply = <&vbat>; - - interrupt-parent = <&gpio1>; - interrupts = <28 IRQ_TYPE_EDGE_RISING>; - - reset-gpios = <&gpio1 16 GPIO_ACTIVE_LOW>; - }; -}; diff --git a/Documentation/devicetree/bindings/iio/health/ti,afe4404.yaml b/Documentation/devicetree/bindings/iio/health/ti,afe4404.yaml new file mode 100644 index 000000000000..187b99b22312 --- /dev/null +++ b/Documentation/devicetree/bindings/iio/health/ti,afe4404.yaml @@ -0,0 +1,51 @@ +# SPDX-License-Identifier: (GPL-2.0 OR BSD-2-Clause) +%YAML 1.2 +--- +$id: http://devicetree.org/schemas/iio/health/ti,afe4404.yaml# +$schema: http://devicetree.org/meta-schemas/core.yaml# + +title: Texas Instruments AFE4404 Heart rate and Pulse Oximeter + +maintainers: + - Andrew F. Davis <afd@ti.com> + +properties: + compatible: + const: ti,afe4403 + + reg: + maxItems: 1 + + tx-supply: + description: Supply to transmitting LEDs. + + interrupts: + maxItems: 1 + description: Connected to ADC_RDY pin. + + reset-gpios: true + +additionalProperties: false + +required: + - compatible + - reg + +examples: + - | + #include <dt-bindings/gpio/gpio.h> + #include <dt-bindings/interrupt-controller/irq.h> + i2c { + #address-cells = <1>; + #size-cells = <0>; + + heart_mon@58 { + compatible = "ti,afe4404"; + reg = <0x58>; + tx-supply = <&vbat>; + interrupt-parent = <&gpio1>; + interrupts = <28 IRQ_TYPE_EDGE_RISING>; + reset-gpios = <&gpio1 16 GPIO_ACTIVE_LOW>; + }; + }; +...